Nitric acid, pentyl ester

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Gas Chromatography

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Normal alkane RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryZB-1900.Harvey and Wenzel, 200915. m/0.25 mm/0.10 μm, Helium, 4. K/min, 185. C @ 15. min; Tstart: 35. C
CapillaryZB-1901.Harvey and Wenzel, 200915. m/0.25 mm/0.10 μm, Helium, 4. K/min, 185. C @ 15. min; Tstart: 35. C
CapillaryZB-1902.Harvey and Wenzel, 200915. m/0.25 mm/0.10 μm, Helium, 4. K/min, 185. C @ 15. min; Tstart: 35. C
CapillaryDB-1903.Schneider and Ballschniter, 199640. C @ 3. min, 3. K/min; Tend: 250. C

Normal alkane RI, non-polar column, custom temperature program

View large format table.

Column type Active phase I Reference Comment
CapillaryDB-1905.Buttery and Takeoka, 2004Column length: 60. m; Column diameter: 0.25 mm; Program: not specified

Normal alkane RI, polar column, custom temperature program

View large format table.

Column type Active phase I Reference Comment
CapillaryDB-Wax1220.Buttery and Takeoka, 2004Column length: 60. m; Column diameter: 0.25 mm; Program: not specified

References

Go To: Top, Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Harvey and Wenzel, 2009
Harvey, S.D.; Wenzel, T.J., Selective retention of explosives and related compounds on gas-chromatographic capillary columns coated with lanthanide(III) beta-diketonate polymers, J. Chromatogr. A, 2009, 1216, 36, 6417-6423, https://doi.org/10.1016/j.chroma.2009.07.008 . [all data]

Schneider and Ballschniter, 1996
Schneider, M.; Ballschniter, K., Separation of Diastereomeric and Enentiomeric Alkyl Nitrates - Systematic Approach to Chiral Discrimination on Cyclodextrin LIPODEX-D, Chem. Eur. J., 1996, 2, 5, 539-544, https://doi.org/10.1002/chem.19960020513 . [all data]

Buttery and Takeoka, 2004
Buttery, R.G.; Takeoka, G.R., Some unusual minor volatile components of tomato, J. Agric. Food Chem., 2004, 52, 20, 6246-6266, https://doi.org/10.1021/jf040176a . [all data]


Notes

Go To: Top, Gas Chromatography, References