Search Results

Search criteria:

Author:Matisova, E.

You may also wish to search for items by Matisova.

19 matching references were found.

Matisova, E.; Krupcik, J.; Cellar, P.; Garaj, J., Quantitative Analysis of Hydrocarbons in Gasolines by Capillary Gas-Liquid Chromatography. I. Isothermal Analysis, J. Chromatogr., 1984, 303, 151-163, https://doi.org/10.1016/S0021-9673(01)96054-6 . [all data]

Matisová, E.; Moravcová, A.; Krupcík; Cellár, P.; Leclercq, P.A., Problems with the reproducibility of retention data on capillary columns with hydrocarbon C87 as the stationary phase, J. Chromatogr., 1988, 454, 65-71, https://doi.org/10.1016/S0021-9673(00)88602-1 . [all data]

Matisová, E.; Rukríglová, M.; Krupcík, J.; Kovacicová, E.; Holotík, S., Identification of alkylbenzenes up to C12 by capillary gas chromatography and combined gas chromatography-mass spectrometry. I. OV-101 as stationary phase, J. Chromatogr., 1988, 455, 301-309, https://doi.org/10.1016/S0021-9673(01)82129-4 . [all data]

Matisová, E.; Krupcík, J., Separation of multi-component mixtures of N-dealkylated degradation products of s-triazine herbicides and their parent compounds by glass capillary gas-liquid chromatography, J. Chromatogr., 1981, 205, 2, 464-469, https://doi.org/10.1016/S0021-9673(00)82678-3 . [all data]

Matisová, E.; Juranyiová, E.; Kurán, P.; Brandsteterová, E.; Kocan, A.; Holotík, S., Analysis of multicomponent mixtures by high-resolution capillary gas chromatography and combined gas chromatography-mass spectrometry. I. Aromatics in a hydrocarbon matrix, J. Chromatogr., 1991, 552, 301-312, https://doi.org/10.1016/S0021-9673(01)95946-1 . [all data]

Matisová, E., Identification of alkylbenzenes by capillary gas chromatography and combined gas chromatography-mass spectrometry, J. Chromatogr., 1988, 438, 131-144, https://doi.org/10.1016/S0021-9673(00)90246-2 . [all data]

Dimov, N.; Matisova, E., Improved method for prediction of gas chromatographic retention indices of C9-C12 alkylbenzenes, J. Chromatogr., 1991, 549, 325-333, https://doi.org/10.1016/S0021-9673(00)91443-2 . [all data]

Krupcik, J.; Matisova, E.; Garaj, J.; Sojak, L.; Brezkin, V.G., Contribution of adsorption to retention data in glass capillary gas chromatography. Part. I. Polar stationary phases, Chromatographia, 1982, 16, 1, 166-168, https://doi.org/10.1007/BF02258890 . [all data]

Lai, J.Y.K.; Matisova, E.; He, D.; Singer, E.; Niki, H., Evaluation of capillary gas chromatography for the measurement of C2-C10 hydrocarbons in urban air samples for air pollution research, J. Chromatogr., 1993, 643, 1-2, 77-90, https://doi.org/10.1016/0021-9673(93)80543-H . [all data]

Matisová, E.; Krupcík, J.; Líska, O.; Szentiványi, N., Qualitative analysis of multi-component s-triazine herbicides by gas-liquid chromatography, J. Chromatogr., 1979, 169, 261-269, https://doi.org/10.1016/0021-9673(75)85049-7 . [all data]

Matisová, E.; Kovacicová, E.; Ha, P.T.; Kolek, E.; Engewald, W., Identification of alkylbenzenes up to C12 by capillary gas chromatography-mass spectrometry. II. Retention indices on OV-101 columns and retention-molecular structure correlations, J. Chromatogr., 1989, 475, 2, 113-123, https://doi.org/10.1016/S0021-9673(01)89667-9 . [all data]

Korytár, P.; Matisová, E.; Lefflerová, H.; Slobodník, J., Large volume injection in fast gas chromatography with on-column injector, J. Hi. Res. Chromatogr., 2000, 23, 2, 149-155, https://doi.org/10.1002/(SICI)1521-4168(20000201)23:2<149::AID-JHRC149>3.0.CO;2-6 . [all data]

Matisová, E.; Kurán, P., Reproducibility of retention indices measurement of alkylbenzenes on crosslinked methyl silicone phase fused silica capillaries, Chromatographia, 1990, 30, 5/6, 328-332, https://doi.org/10.1007/BF02319717 . [all data]

Kirchner, M.; Matisová, E.; Otrekal, R.; Hercegová, A.; de Zeeuw, J., Search on ruggedness of fast gas chromatography-mass spectrometry in pesticide residues analysis, J. Chromatogr. A, 2005, 1084, 1-2, 63-70, https://doi.org/10.1016/j.chroma.2004.10.043 . [all data]

Kirchner, M.; Matisová, E.; Hrouzková, S.; de Zeeuw, J., Possibilities and limitations of quadrupole mass spectrometric detector in fast gas chromatography, J. Chromatogr. A, 2005, 1090, 1-2, 126-132, https://doi.org/10.1016/j.chroma.2005.06.090 . [all data]

Hercegova, A.; Domotorova, M.; Kruzilicova, D.; Matisova, E., Comparison of sample preparation methods combined with fast gas chromatography - mass spectrometry for ultratrace analysis of pesticide residues in baby food, J. Sep. Sci., 2006, 29, 8, 1102-1109, https://doi.org/10.1002/jssc.200500422 . [all data]

Korenkova, E.; Matisova, E.; Slobodnik, J., Study on the feasibility of coupling large-volume injection to fast gas chromatography with mass spectrometric detection for analysis of organochlorine pesticides, J. Sep. Sci., 2003, 26, 12-13, 1193-1197, https://doi.org/10.1002/jssc.200301269 . [all data]

Sedlackova, B.; Kakalikova, L.; Matisova, E.; Farkas, P.; Dobos, A., Analysis of volatile compounds in various wines, Analytica Methos and Instrumentation, 1995, 2, 2, 106-108. [all data]

Hercegova, A.; Domotorova, M.; Hrouzkova, S.; Matisova, E., Study on pesticide residues in apples, apple-based baby food, and their behaviour during processing using fast GC-MS multiresidue analysis, Int. J. Environ. Anal. Chem., 2007, 87, 13-14, 957-969, https://doi.org/10.1080/03067310701461763 . [all data]