2,4-Dichlorobenzyl alcohol, n-propyl ether


Van Den Dool and Kratz RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase VF-5MSCP Sil 5 CBCP Sil 5 CBCP Sil 5 CBCP Sil 5 CB
Column length (m) 30.25.25.25.25.
Carrier gas HeH2H2H2H2
Substrate      
Column diameter (mm) 0.250.220.220.220.22
Phase thickness (μm) 0.250.120.120.120.12
Tstart (C) 60.100.100.100.100.
Tend (C) 270.    
Heat rate (K/min)  3.5.7.9.
Initial hold (min)      
Final hold (min)      
I 1503.1463.1461.1464.1465.
ReferenceTodua, 2011Wells, Gillespie, et al., 1985Wells, Gillespie, et al., 1985Wells, Gillespie, et al., 1985Wells, Gillespie, et al., 1985
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase CP Sil 5 CBCP Sil 5 CBCP Sil 5 CBCP Sil 5 CBCP Sil 5 CB
Column length (m) 25.25.25.25.25.
Carrier gas H2H2H2H2H2
Substrate      
Column diameter (mm) 0.220.220.220.220.22
Phase thickness (μm) 0.120.120.120.120.12
Tstart (C) 120.120.120.120.80.
Tend (C)      
Heat rate (K/min) 3.5.7.9.3.
Initial hold (min)      
Final hold (min)      
I 1473.1472.1472.1473.1455.
ReferenceWells, Gillespie, et al., 1985Wells, Gillespie, et al., 1985Wells, Gillespie, et al., 1985Wells, Gillespie, et al., 1985Wells, Gillespie, et al., 1985
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillary
Active phase CP Sil 5 CBCP Sil 5 CBCP Sil 5 CB
Column length (m) 25.25.25.
Carrier gas H2H2H2
Substrate    
Column diameter (mm) 0.220.220.22
Phase thickness (μm) 0.120.120.12
Tstart (C) 80.80.80.
Tend (C)    
Heat rate (K/min) 5.7.9.
Initial hold (min)    
Final hold (min)    
I 1458.1460.1462.
ReferenceWells, Gillespie, et al., 1985Wells, Gillespie, et al., 1985Wells, Gillespie, et al., 1985
Comment MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Van Den Dool and Kratz RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Todua, 2011
Todua, N.G., Retention Data. NIST Mass Spectrometry Data Center., NIST Mass Spectrometry Data Center, 2011. [all data]

Wells, Gillespie, et al., 1985
Wells, D.E.; Gillespie, M.J.; Porter, A.E.A., Dichlorobenzyl alkyl ether homologs as retention index markers and internal standards for the analysis of environmental samples using capillary gas chromatography, J. Hi. Res. Chromatogr. Chromatogr. Comm., 1985, 8, 8, 443-449, https://doi.org/10.1002/jhrc.1240080818 . [all data]


Notes

Go To: Top, Van Den Dool and Kratz RI, non-polar column, temperature ramp, References