Trichloroethylene

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Normal alkane RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase HP-5 MSSPB-1SPB-1BP-1SE-54
Column length (m) 30.30.30.50.36.
Carrier gas HeliumHeHeHe 
Substrate      
Column diameter (mm) 0.250.250.250.220.25
Phase thickness (μm) 0.250.250.250.750.25
Tstart (C) 35.40.40.50.35.
Tend (C) 300.200.200.200.240.
Heat rate (K/min) 3.3.3.5.5.
Initial hold (min) 5.10.10.  
Final hold (min) 15.    
I 701.680.680.691.722.
ReferenceKotowska, Zalikowski, et al., 2012Vichi, Castellote, et al., 2003Vichi, Pizzale, et al., 2003Health Safety Executive, 2000Huang, Liang, et al., 1996
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillary
Active phase DB-1SF-96
Column length (m) 50.111.
Carrier gas  Nitrogen
Substrate   
Column diameter (mm) 0.320.76
Phase thickness (μm)   
Tstart (C) 0. 
Tend (C) 250.130.
Heat rate (K/min) 3.3.
Initial hold (min)  8.
Final hold (min)  40.
I 686.690.
ReferenceHabu, Flath, et al., 1985Donetzhuber, Johansson, et al., 1976
Comment MSDC-RI MSDC-RI

References

Go To: Top, Normal alkane RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Kotowska, Zalikowski, et al., 2012
Kotowska, U.; Zalikowski, M.; Isidorov, V.A., HS-SPME/GC-MS analysis of volatile and semi-volatile organic compounds emitted from municipal sewage sludge, Environ. Monit. Asses., 2012, 184, 5, 2893-2907, https://doi.org/10.1007/s10661-011-2158-8 . [all data]

Vichi, Castellote, et al., 2003
Vichi, S.; Castellote, A.I.; Pizzale, L.; Conte, L.S.; Buxaderas, S.; López-Tamames, E., Analysis of virgin olive oil volatile compounds by headspace solid-phase microextraction coupled to gas chromatography with mass spectrometric and flame ionization detection, J. Chromatogr. A, 2003, 983, 1-2, 19-33, https://doi.org/10.1016/S0021-9673(02)01691-6 . [all data]

Vichi, Pizzale, et al., 2003
Vichi, S.; Pizzale, L.; Conte, L.S.; Buxaderas, S.; López-Tamames, E., Solid-phase microextraction in the analysis of virgin olive oil volatile fraction: characterization of virgin olive oils from two distinct geographical areas of Northern Italy, J. Agric. Food Chem., 2003, 51, 22, 6572-6577, https://doi.org/10.1021/jf030269c . [all data]

Health Safety Executive, 2000
Health Safety Executive, MDHS 96 Volatile organic compounds in air - Laboratory method using pumed solid sorbent tubes, solvent desorption and gas chromatography in Methods for the Determination of Hazardous Substances (MDHS) guidance, Crown, Colegate, Norwich, 2000, 1-24, retrieved from http://www.hse.gov.uk/pubns/mdhs/pdfs/mdhs96.pdf. [all data]

Huang, Liang, et al., 1996
Huang, C.; Liang, H.; Han, S., The analysis of organic compounds in waste water by gas extraction/thermal desorption/gas chromatography-mass spectrometry, Chin. J. Chromatogr., 1996, 14, 6, 421-424. [all data]

Habu, Flath, et al., 1985
Habu, T.; Flath, R.A.; Mon, T.R.; Morton, J.F., Volatile components of Rooibos tea (Aspalathus linearis), J. Agric. Food Chem., 1985, 33, 2, 249-254, https://doi.org/10.1021/jf00062a024 . [all data]

Donetzhuber, Johansson, et al., 1976
Donetzhuber, A.; Johansson, K.; Sandstroem, C., Gas phase characterization of wood, pulp, and paper, Appl. Polymer Symp., 1976, 28, 889-901. [all data]


Notes

Go To: Top, Normal alkane RI, non-polar column, temperature ramp, References