Beryllium hydride


Gas Phase Heat Capacity (Shomate Equation)

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Cp° = A + B*t + C*t2 + D*t3 + E/t2
H° − H°298.15= A*t + B*t2/2 + C*t3/3 + D*t4/4 − E/t + F − H
S° = A*ln(t) + B*t + C*t2/2 + D*t3/3 − E/(2*t2) + G
    Cp = heat capacity (J/mol*K)
    H° = standard enthalpy (kJ/mol)
    S° = standard entropy (J/mol*K)
    t = temperature (K) / 1000.

View plot Requires a JavaScript / HTML 5 canvas capable browser.

Temperature (K) 298. to 1200.1200. to 6000.
A -0.14000058.43918
B 93.635832.090766
C -55.43507-0.408548
D 11.949880.027544
E 0.642081-10.01558
F 124.021785.23854
G 151.0043213.7225
H 125.5200125.5200
ReferenceChase, 1998Chase, 1998
Comment Data last reviewed in December, 1960 Data last reviewed in December, 1960
Temperature
(K)
Cp
(J/mol*K)

(J/mol*K)
-(G° - H°298.15)/T
(J/mol*K)
H° - H°298.15
(kJ/mol)
298.30.39173.1173.1-0.00
300.30.42173.3173.10.06
400.33.22182.4174.33.23
500.36.88190.2176.76.73
600.40.45197.2179.610.60
700.43.65203.7182.614.81
800.46.41209.7185.619.31
900.48.73215.3188.624.07
1000.50.65220.6191.529.05
1100.52.22225.5194.434.19
1200.53.49230.1197.239.48
Temperature
(K)
Cp
(J/mol*K)

(J/mol*K)
-(G° - H°298.15)/T
(J/mol*K)
H° - H°298.15
(kJ/mol)
1200.53.45230.1197.239.48
1300.54.60234.4199.944.88
1400.55.53238.5202.550.39
1500.56.30242.4205.055.98
1600.56.94246.0207.561.64
1700.57.48249.5209.867.37
1800.57.95252.8212.173.14
1900.58.35255.9214.478.95
2000.58.70258.9216.584.81
2100.59.01261.8218.690.69
2200.59.29264.5220.696.61
2300.59.53267.2222.6102.5
2400.59.75269.7224.5108.5
2500.59.94272.2226.4114.5
2600.60.12274.5228.2120.5
2700.60.27276.8229.9126.5
2800.60.42279.0231.6132.6
2900.60.55281.1233.3138.6
3000.60.67283.2234.9144.7
3100.60.77285.2236.5150.7
3200.60.87287.1238.1156.8
3300.60.96289.0239.6162.9
3400.61.04290.8241.1169.0
3500.61.12292.6242.5175.1
3600.61.18294.3243.9181.2
3700.61.25296.0245.3187.4
3800.61.30297.6246.7193.5
3900.61.35299.2248.0199.6
4000.61.40300.7249.3205.8
4100.61.45302.2250.6211.9
4200.61.49303.7251.8218.0
4300.61.52305.2253.0224.2
4400.61.56306.6254.2230.3
4500.61.59308.0255.4236.5
4600.61.62309.3256.6242.7
4700.61.65310.7257.7248.8
4800.61.67312.0258.8255.0
4900.61.70313.2259.9261.2
5000.61.72314.5261.0267.3
5100.61.74315.7262.1273.5
5200.61.77316.9263.1279.7
5300.61.79318.1264.1285.9
5400.61.81319.2265.1292.0
5500.61.83320.4266.1298.2
5600.61.85321.5267.1304.4
5700.61.88322.6268.1310.6
5800.61.90323.6269.0316.8
5900.61.92324.7270.0323.0
6000.61.95325.7270.9329.2

References

Go To: Top, Gas Phase Heat Capacity (Shomate Equation), Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Chase, 1998
Chase, M.W., Jr., NIST-JANAF Themochemical Tables, Fourth Edition, J. Phys. Chem. Ref. Data, Monograph 9, 1998, 1-1951. [all data]


Notes

Go To: Top, Gas Phase Heat Capacity (Shomate Equation), References


Copyright for NIST Standard Reference Data is governed by the Standard Reference Data Act.