Amantadine

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type PackedPackedPackedPackedPacked
Active phase PMS-1000PMS-1000Apiezon LOV-101Apiezon L
Column length (m) 2.1.1.1.1.
Carrier gas N2N2N2N2N2
Substrate Chromaton N-AW-DMCSChromatron N-AWChromatron N-AWChromaton N-AWChromaton N-AW
Column diameter (mm)      
Phase thickness (μm)      
Temperature (C) 230.160.160.200.200.
I 1256.1266.1216.1292.1240.
ReferenceArutyunov, Kudryashov, et al., 2004Kurbatova, Moiseev, et al., 1999Kurbatova, Moiseev, et al., 1999Kurbatova, Yashkin, et al., 1999Kurbatova, Yashkin, et al., 1999
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPackedCapillaryPacked
Active phase OV-101Apiezon LOV-101SE-30
Column length (m) 1.1.50.2.
Carrier gas   N2N2
Substrate Chromaton N-AWChromaton N-AW 1% se-30 on Anachrom ABS(80-100mesh)
Column diameter (mm)   0.25 
Phase thickness (μm)     
Temperature (C) 200.200.200.140.
I 1292.1240.1297.1272.
ReferenceKurbatova, Moiseev, et al., 1998Kurbatova, Moiseev, et al., 1998Suslov, Rudenko, et al., 1988Musumarra, Scarlata, et al., 1987
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Arutyunov, Kudryashov, et al., 2004
Arutyunov, Y.I.; Kudryashov, S.Y.; Onuchak, L.A., Analysis of Mixtures Containing Unknown Components by Gas Chromatography: Determination of Molecular Mass, J. Anal. Chem. USSR (Engl. Transl.), 2004, 59, 4, 358-365. [all data]

Kurbatova, Moiseev, et al., 1999
Kurbatova, S.V.; Moiseev, I.K.; Kudryashov, S.Yu.; Yashkin, S.N.; Postnikova, I.V., Chromatographic examination of the intermediate products of midantane synthesis, J. Anal. Chem. USSR (Engl. Transl.), 1999, 54, 1, 75-77. [all data]

Kurbatova, Yashkin, et al., 1999
Kurbatova, S.V.; Yashkin, S.N.; Moiseev, I.K.; Zemtsova, M.N., A study of the cell effect for adamantane derivatives by gas-liquid chromatography, Russ. J. Phys. Chem. (Engl. Transl.), 1999, 73, 9, 1486-1489. [all data]

Kurbatova, Moiseev, et al., 1998
Kurbatova, S.V.; Moiseev, I.K.; Zemtsova, M.N.; Kudryashov, S.Yu., Gas chromatography of aminoadamantanes, J. Anal. Chem. USSR (Engl. Transl.), 1998, 53, 8, 732-734. [all data]

Suslov, Rudenko, et al., 1988
Suslov, I.A.; Rudenko, B.A.; Arzamastsev, A.P., Capillary chromatography of adamantane derivatives, Zh. Anal. Khim., 1988, 43, 328-332. [all data]

Musumarra, Scarlata, et al., 1987
Musumarra, G.; Scarlata, G.; Romano, G.; Cappello, G.; Clementi, S.; Giulietti, G., Qualitative organic analysis. Part 2. Identification of drugs by principal components analysis of standardized TLC data in four eluent systems and of retention indices on SE 30, J. Anal. Toxicol., 1987, 11, 4, 154-163, https://doi.org/10.1093/jat/11.4.154 . [all data]


Notes

Go To: Top, Kovats' RI, non-polar column, isothermal, References