NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryPackedPackedPacked
Active phase Carbowax 20MCarbowax 20MSP-1000SP-1000SP-1000
Column length (m) 31.330.3.3.3.
Carrier gas  HeHeHeHe
Substrate   Chromosorb W DMCSChromosorb W DMCSChromosorb W DMCS
Column diameter (mm) 0.530.32   
Phase thickness (μm) 0.540.54   
Temperature (C) 70.50.100.125.75.
I 898.898.904.35909.11897.56
ReferenceAnnino and Villalobos, 1999Villalobos, 1995Castello and Gerbino, 1988Castello and Gerbino, 1988Castello and Gerbino, 1988
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type Packed
Active phase Carbowax 20M
Column length (m) 2.
Carrier gas N2
Substrate Kieselgur (60-100 mesh)
Column diameter (mm)  
Phase thickness (μm)  
Temperature (C) 75.
I 891.
ReferenceGoebel, 1982
Comment MSDC-RI

References

Go To: Top, Kovats' RI, polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Annino and Villalobos, 1999
Annino, R.; Villalobos, R., A strategy for the simplification and solution of complex chromatographic analysis problems utilizing two-dimensional mapping of retention indexes followed by computer modeling of heart cuts from serially coupled columns containing different stationary phases, J. Hi. Res. Chromatogr., 1999, 22, 10, 589-593. [all data]

Villalobos, 1995
Villalobos, R., A window diagram for key component analysis in on-line gas chromatography, J. Hi. Res. Chromatogr., 1995, 18, 6, 343-347, https://doi.org/10.1002/jhrc.1240180604 . [all data]

Castello and Gerbino, 1988
Castello, G.; Gerbino, T.C., Effect of Temperature on the Gas Chromatographic Separation of Halogenated Compounds on Polar and Non-Polar Stationary Phases, J. Chromatogr., 1988, 437, 33-45, https://doi.org/10.1016/S0021-9673(00)90369-8 . [all data]

Goebel, 1982
Goebel, K.-J., Gaschromatographische Identifizierung Niedrig Siedender Substanzen Mittels Retentionsindices und Rechnerhilfe, J. Chromatogr., 1982, 235, 1, 119-127, https://doi.org/10.1016/S0021-9673(00)95793-5 . [all data]


Notes

Go To: Top, Kovats' RI, polar column, isothermal, References