Ethanol

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Normal alkane RI, polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase Carbowax 20MCarbowax 20MCarbowax 20MOV-351OV-351
Column length (m) 30.30.30.25.25.
Carrier gas HeliumHeliumHeliumN2N2
Substrate      
Column diameter (mm) 0.250.250.250.330.33
Phase thickness (μm) 0.250.250.25  
Temperature (C) 100.60.80.100.120.
I 926.936.932.927.910.
ReferenceSun, Siepmann, et al., 2006Sun, Siepmann, et al., 2006Sun, Siepmann, et al., 2006Korhonen, 1985Korhonen, 1985
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryPacked
Active phase OV-351Carbowax 20M
Column length (m) 25. 
Carrier gas N2 
Substrate   
Column diameter (mm) 0.33 
Phase thickness (μm)   
Temperature (C) 140.100.
I 890.917.
ReferenceKorhonen, 1985Yabumoto, Jennings, et al., 1977
Comment MSDC-RI MSDC-RI

References

Go To: Top, Normal alkane RI, polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Sun, Siepmann, et al., 2006
Sun, L.; Siepmann, J.I.; Klotz, W.L.; Schure, M.R., retention in gas-liquid chromatography with a polyethylene oxide stationary phase: molecular simulation and experiment, J. Chromatogr. A, 2006, 1126, 1-2, 373-380, https://doi.org/10.1016/j.chroma.2006.05.084 . [all data]

Korhonen, 1985
Korhonen, I.O.O., Gas-liquid chromatographic analyses. XXXIX. ω-Chloroethanols on low-polarity (SE-30) and polar (OV-351) capillary columns, J. Chromatogr., 1985, 324, 181-191, https://doi.org/10.1016/S0021-9673(01)81317-0 . [all data]

Yabumoto, Jennings, et al., 1977
Yabumoto, K.; Jennings, W.G.; Yamaguchi, M., Gas chromatographic retention as identification criteria, Anal. Biochem., 1977, 78, 1, 244-251, https://doi.org/10.1016/0003-2697(77)90029-X . [all data]


Notes

Go To: Top, Normal alkane RI, polar column, isothermal, References