Methyl 2,4-dichlorobutanoate


Gas Chromatography

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Kovats' RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillaryOV-101100.1056.Haken and Korhonen, 1984N2; Column length: 25. m; Column diameter: 0.3 mm
CapillaryOV-101120.1047.Haken and Korhonen, 1984N2; Column length: 25. m; Column diameter: 0.3 mm
CapillaryOV-10180.1057.Haken and Korhonen, 1984N2; Column length: 25. m; Column diameter: 0.3 mm

References

Go To: Top, Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Haken and Korhonen, 1984
Haken, J.K.; Korhonen, I.O.O., Gas chromatography of homologous esters. XXIV. Studies of chlorinated methyl propanoates and butanoates on a non-polar capillary column, J. Chromatogr., 1984, 284, 474-477, https://doi.org/10.1016/S0021-9673(01)87849-3 . [all data]


Notes

Go To: Top, Gas Chromatography, References