Fluoroboroxin


Gas Phase Heat Capacity (Shomate Equation)

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Cp° = A + B*t + C*t2 + D*t3 + E/t2
H° − H°298.15= A*t + B*t2/2 + C*t3/3 + D*t4/4 − E/t + F − H
S° = A*ln(t) + B*t + C*t2/2 + D*t3/3 − E/(2*t2) + G
    Cp = heat capacity (cal/mol*K)
    H° = standard enthalpy (kcal/mol)
    S° = standard entropy (cal/mol*K)
    t = temperature (K) / 1000.

View plot Requires a JavaScript / HTML 5 canvas capable browser.

Temperature (K) 298. to 1200.1200. to 6000.
A 4.31934147.47230
B 80.499591.176480
C -58.19601-0.229716
D 15.653300.015478
E -0.071783-6.494900
F -386.6240-411.9300
G 58.51709110.8780
H -382.0000-382.0000
ReferenceChase, 1998Chase, 1998
Comment Data last reviewed in December, 1965 Data last reviewed in December, 1965
Temperature
(K)
Cp
(cal/mol*K)

(cal/mol*K)
-(G° - H°298.15)/T
(cal/mol*K)
H° - H°298.15
(kcal/mol)
298.22.7575.2375.25-0.00
300.22.8675.3975.250.04
400.27.7682.6676.212.58
500.31.6989.2978.175.56
600.34.8595.3680.548.89
700.37.38100.983.0612.51
800.39.38106.185.6216.35
900.40.95110.888.1620.37
1000.42.20115.290.6424.53
1100.43.23119.293.0628.80
1200.44.12123.095.4033.17
Temperature
(K)
Cp
(cal/mol*K)

(cal/mol*K)
-(G° - H°298.15)/T
(cal/mol*K)
H° - H°298.15
(kcal/mol)
1200.44.07123.095.4033.17
1300.44.80126.697.6737.62
1400.45.40129.999.8542.13
1500.45.89133.1102.046.69
1600.46.29136.1104.051.30
1700.46.64138.9106.055.95
1800.46.93141.6107.960.63
1900.47.19144.1109.765.33
2000.47.41146.5111.570.06
2100.47.60148.8113.274.81
2200.47.77151.1114.979.58
2300.47.92153.2116.584.37
2400.48.06155.2118.189.17
2500.48.18157.2119.693.98
2600.48.29159.1121.198.80
2700.48.39160.9122.5103.6
2800.48.48162.7123.9108.5
2900.48.56164.4125.3113.3
3000.48.63166.0126.6118.2
3100.48.70167.6127.9123.1
3200.48.76169.2129.2127.9
3300.48.81170.7130.4132.8
3400.48.86172.1131.6137.7
3500.48.91173.5132.8142.6
3600.48.95174.9134.0147.5
3700.48.99176.3135.1152.4
3800.49.03177.6136.2157.3
3900.49.06178.8137.3162.2
4000.49.09180.1138.3167.1
4100.49.11181.3139.4172.0
4200.49.14182.5140.4176.9
4300.49.16183.6141.4181.8
4400.49.18184.8142.3186.7
4500.49.20185.9143.3191.7
4600.49.22187.0144.2196.6
4700.49.24188.0145.1201.5
4800.49.26189.1146.1206.4
4900.49.27190.1146.9211.4
5000.49.29191.1147.8216.3
5100.49.30192.0148.7221.2
5200.49.31193.0149.5226.1
5300.49.33193.9150.3231.1
5400.49.34194.9151.2236.0
5500.49.35195.8152.0240.9
5600.49.37196.7152.8245.9
5700.49.38197.5153.5250.8
5800.49.40198.4154.3255.8
5900.49.41199.2155.0260.7
6000.49.42200.1155.8265.6

References

Go To: Top, Gas Phase Heat Capacity (Shomate Equation), Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Chase, 1998
Chase, M.W., Jr., NIST-JANAF Themochemical Tables, Fourth Edition, J. Phys. Chem. Ref. Data, Monograph 9, 1998, 1-1951. [all data]


Notes

Go To: Top, Gas Phase Heat Capacity (Shomate Equation), References


Copyright for NIST Standard Reference Data is governed by the Standard Reference Data Act.