Fluoroboroxin


Gas Phase Heat Capacity (Shomate Equation)

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Cp° = A + B*t + C*t2 + D*t3 + E/t2
H° − H°298.15= A*t + B*t2/2 + C*t3/3 + D*t4/4 − E/t + F − H
S° = A*ln(t) + B*t + C*t2/2 + D*t3/3 − E/(2*t2) + G
    Cp = heat capacity (J/mol*K)
    H° = standard enthalpy (kJ/mol)
    S° = standard entropy (J/mol*K)
    t = temperature (K) / 1000.

View plot Requires a JavaScript / HTML 5 canvas capable browser.

Temperature (K) 298. to 1200.1200. to 6000.
A 18.07212198.6241
B 336.81034.922392
C -243.4921-0.961132
D 65.493410.064761
E -0.300340-27.17466
F -1617.635-1723.515
G 244.8355463.9136
H -1598.288-1598.288
ReferenceChase, 1998Chase, 1998
Comment Data last reviewed in December, 1965 Data last reviewed in December, 1965
Temperature
(K)
Cp
(J/mol*K)

(J/mol*K)
-(G° - H°298.15)/T
(J/mol*K)
H° - H°298.15
(kJ/mol)
298.95.17314.8314.8-0.02
300.95.63315.4314.80.17
400.116.2345.9318.910.80
500.132.6373.6327.123.27
600.145.8399.0337.037.21
700.156.4422.3347.552.34
800.164.7443.7358.268.42
900.171.3463.5368.885.23
1000.176.6481.9379.2102.6
1100.180.9498.9389.4120.5
1200.184.6514.8399.2138.8
Temperature
(K)
Cp
(J/mol*K)

(J/mol*K)
-(G° - H°298.15)/T
(J/mol*K)
H° - H°298.15
(kJ/mol)
1200.184.4514.8399.2138.8
1300.187.5529.7408.6157.4
1400.189.9543.7417.8176.3
1500.192.0556.9426.6195.4
1600.193.7569.3435.2214.7
1700.195.1581.1443.4234.1
1800.196.4592.3451.4253.7
1900.197.4602.9459.1273.4
2000.198.3613.1466.5293.1
2100.199.2622.8473.7313.0
2200.199.9632.1480.7333.0
2300.200.5641.0487.5353.0
2400.201.1649.5494.1373.1
2500.201.6657.7500.4393.2
2600.202.0665.6506.6413.4
2700.202.5673.3512.7433.6
2800.202.8680.6518.5453.9
2900.203.2687.8524.3474.2
3000.203.5694.7529.8494.5
3100.203.7701.3535.2514.9
3200.204.0707.8540.5535.3
3300.204.2714.1545.7555.7
3400.204.4720.2550.7576.1
3500.204.6726.1555.7596.6
3600.204.8731.9560.5617.0
3700.205.0737.5565.2637.5
3800.205.1743.0569.8658.0
3900.205.3748.3574.3678.6
4000.205.4753.5578.7699.1
4100.205.5758.6583.1719.6
4200.205.6763.5587.3740.2
4300.205.7768.4591.4760.7
4400.205.8773.1595.5781.3
4500.205.9777.7599.5801.9
4600.205.9782.2603.4822.5
4700.206.0786.7607.3843.1
4800.206.1791.0611.1863.7
4900.206.2795.3614.8884.3
5000.206.2799.4618.4904.9
5100.206.3803.5622.0925.6
5200.206.3807.5625.6946.2
5300.206.4811.4629.0966.8
5400.206.4815.3632.4987.5
5500.206.5819.1635.81008.
5600.206.6822.8639.11029.
5700.206.6826.5642.41049.
5800.206.7830.1645.61070.
5900.206.7833.6648.71091.
6000.206.8837.1651.81111.

References

Go To: Top, Gas Phase Heat Capacity (Shomate Equation), Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Chase, 1998
Chase, M.W., Jr., NIST-JANAF Themochemical Tables, Fourth Edition, J. Phys. Chem. Ref. Data, Monograph 9, 1998, 1-1951. [all data]


Notes

Go To: Top, Gas Phase Heat Capacity (Shomate Equation), References


Copyright for NIST Standard Reference Data is governed by the Standard Reference Data Act.