NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Normal alkane RI, non-polar column, custom temperature program

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase HP-5 MSPolydimethyl siloxane with 5 % Ph groupsPolydimethyl siloxane with 5 % Ph groupsMethyl SiliconeCP Sil 2
Column length (m) 30.   55.
Carrier gas Helium   N2
Substrate      
Column diameter (mm) 0.25   0.25
Phase thickness (μm) 0.25   0.25
Program not specifiednot specifiednot specifiednot specified40C(3min) => 20C/min => 80C => 2C/min => 240C(45min)
I 1011.1014.1022.964.988.
ReferenceKotowska, Zalikowski, et al., 2012Robinson, Adams, et al., 2012Robinson, Adams, et al., 2012Yu and Zazhi, 2005Fuhrer, Deissler, et al., 1997
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase Polydimethyl siloxanesDB-5DB-1SPB-1PTE-5
Column length (m)  30.60.30.25.
Carrier gas  He   
Substrate      
Column diameter (mm)   0.320.320.20
Phase thickness (μm)   0.25 0.33
Program not specifiednot specifiednot specifiednot specified50 0C (2 min) 30 0C/min -> 200 0C 8 0C/min -> 280 0C (10 min)
I 1005.1047.986.982.1045.
ReferenceZenkevich and Chupalov, 1996Sorimachi, Tanabe, et al., 1995Ciccioli, Cecinato, et al., 1994Vezzani, Moretti, et al., 1994Nakano, Fujimori, et al., 1992
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase Ultra-2OV-1OV-1, SE-30, Methyl silicone, SP-2100, OV-101, DB-1, etc.OV-1, SE-30, Methyl silicone, SP-2100, OV-101, DB-1, etc.OV-1, SE-30, Methyl silicone, SP-2100, OV-101, DB-1, etc.
Column length (m) 25.50.50.50.50.
Carrier gas  HydrogenHydrogenHydrogenHydrogen
Substrate      
Column diameter (mm) 0.200.320.320.320.32
Phase thickness (μm) 0.33    
Program 50 0C (2 min) 30 0C/min -> 200 0C 8 0C/min -> 280 0C (10 min)not specifiednot specifiednot specifiednot specified
I 1021.981.981.981.982.
ReferenceNakano, Fujimori, et al., 1992Waggott and Davies, 1984Waggott and Davies, 1984Waggott and Davies, 1984Waggott and Davies, 1984
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Normal alkane RI, non-polar column, custom temperature program, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Kotowska, Zalikowski, et al., 2012
Kotowska, U.; Zalikowski, M.; Isidorov, V.A., HS-SPME/GC-MS analysis of volatile and semi-volatile organic compounds emitted from municipal sewage sludge, Environ. Monit. Asses., 2012, 184, 5, 2893-2907, https://doi.org/10.1007/s10661-011-2158-8 . [all data]

Robinson, Adams, et al., 2012
Robinson, A.L.; Adams, D.O.; Boss, P.K.; Heymann, H.; Solomon, P.S.; Trengove, R.D., Influence of geographic origine on the sensory characteristics and wine composition of Vitus viniferas cv. Cabernet Sauvignon wines from Australia (Supplemental data), Am. J. Enol. Vitic., 2012, 64, 4, 467-476, https://doi.org/10.5344/ajev.2012.12023 . [all data]

Yu and Zazhi, 2005
Yu, H.; Zazhi, J., Relationship between chromatogram retention index and toxicity of chlorinated phenols and chlorinated benzenes to Guppy, J. Enviropn. Health (Chinese), 2005, 22, 6, 441-444. [all data]

Fuhrer, Deissler, et al., 1997
Fuhrer, U.; Deissler, A.; Schreitmuller, J.; Ballschmiter, K., Analysis of Halogenated Methoxybenzenes and Hexachlorobenzene (HCB) in the Picogram m-3 Range in Marine Air, Chromatographia, 1997, 45, 1, 414-427, https://doi.org/10.1007/BF02505594 . [all data]

Zenkevich and Chupalov, 1996
Zenkevich, I.G.; Chupalov, A.A., New Possibilities of Chromato Mass Pectrometric Identification of Organic Compounds Using Increments of Gas Chromatographic Retention Indices of Molecular Structural Fragments, Zh. Org. Khim. (Rus.), 1996, 32, 5, 656-666. [all data]

Sorimachi, Tanabe, et al., 1995
Sorimachi, J.; Tanabe, A.; Mitobe, H.; Kuniaki, K.; Masaaki, S., Programmed temperature retention indices for volatile organic compounds on headspace GC/MS analysis, Niigata-ken Eisei Kogai Kenkyusho Nenpo, 1995, 11, 75-79. [all data]

Ciccioli, Cecinato, et al., 1994
Ciccioli, P.; Cecinato, A.; Brancaleoni, E.; Brachetti, A.; Frattoni, M.; Sparapani, R., Composition and Distribution of Polar and Non-Polar VOCs in Urban, Rural, Forest and Remote Areas, Eur Commission EUR, 1994, 549-568. [all data]

Vezzani, Moretti, et al., 1994
Vezzani, S.; Moretti, P.; Castello, G., Fast and Accurate Method for the Automatic Prediction of Programmed-Temperature Retention Times, J. Chromatogr. A, 1994, 677, 2, 331-343, https://doi.org/10.1016/0021-9673(94)80161-4 . [all data]

Nakano, Fujimori, et al., 1992
Nakano, T.; Fujimori, K.; Takaishi, Y.; Okuno, T., GC/MS-SIM analysis of polychlorobenzenes, polychlorophenols and polychloronaphthalenes, Report of the Environmental Science Institute of Hyogo Prefecture, 1992, 24, 30-37. [all data]

Waggott and Davies, 1984
Waggott, A.; Davies, I.W., Identification of organic pollutants using linear temperature programmed retention indices (LTPRIs) - Part II, 1984, retrieved from http://dwi.defra.gov.uk/research/completed-research/reports/dwi0383.pdf. [all data]


Notes

Go To: Top, Normal alkane RI, non-polar column, custom temperature program, References