Cyclohexane, 1,3,5-trimethyl-, (1α,3α,5β)-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryPackedCapillaryCapillary
Active phase SqualaneSqualaneSqualaneVacuum Grease Oil (VM-4)Vacuum Grease Oil (VM-4)
Column length (m) 50.50.1.  
Carrier gas HeHeHe  
Substrate   Chromaton N-AW-HMDS  
Column diameter (mm) 0.220.22   
Phase thickness (μm)      
Temperature (C) 50.70.100.35.45.
I 859.4865.1859.858.862.
ReferenceLunskii and Paizanskaya, 1988Lunskii and Paizanskaya, 1988Nabivach and Kirilenko, 1980Sidorov, Petrova, et al., 1972Sidorov, Petrova, et al., 1972
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryPackedPacked
Active phase Vacuum Grease Oil (VM-4)Vacuum Grease Oil (VM-4)Vacuum Grease Oil (VM-4)Vacuum Grease Oil (VM-4)SE-30
Column length (m)      
Carrier gas     N2
Substrate      
Column diameter (mm)      
Phase thickness (μm)      
Temperature (C) 50.58.68.35.130.
I 863.866.869.858.840.
ReferenceSidorov, Petrova, et al., 1972Sidorov, Petrova, et al., 1972Sidorov, Petrova, et al., 1972Sidorov, Ivanova, et al., 1971Mitra and Saha, 1970
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type Packed
Active phase Methyl Silicone
Column length (m)  
Carrier gas  
Substrate  
Column diameter (mm)  
Phase thickness (μm)  
Temperature (C) 130.
I 840.
ReferenceAntheaume and Guiochon, 1965
Comment MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Lunskii and Paizanskaya, 1988
Lunskii, M.Kh.; Paizanskaya, I.L., Identification of hydrocarbons C1-C9 of petrol fractions of oils and condensates in the use of capillary columns with dinonylphthalate, Zh. Anal. Khim., 1988, 43, 127-135. [all data]

Nabivach and Kirilenko, 1980
Nabivach, V.M.; Kirilenko, A.V., Relationship between the gas chromatographic behaviour and the molecular structure of hydrocarbon samples and various stationary phases. Part II. Correlation between the retention index, physicochemical properties and molecular structure, Chromatographia, 1980, 13, 2, 93-100, https://doi.org/10.1007/BF02263060 . [all data]

Sidorov, Petrova, et al., 1972
Sidorov, R.I.; Petrova, V.I.; Ivanova, M.P., Qualitative analysis of wide-boiling fraction C5-C10 with capillary chromatography in Processes in chromatographic columns. Vol.17, 1972, 14-25. [all data]

Sidorov, Ivanova, et al., 1971
Sidorov, R.I.; Ivanova, M.P.; Petrova, V.I., Temperature dependence of cycloalkane's retention and its using in identification of structure, Gazovaya Khromatografiya, 1971, 15, 18-26. [all data]

Mitra and Saha, 1970
Mitra, G.D.; Saha, N.C., Determination of Retention Indices of Saturated Hydrocarbons by Graphical Methods, J. Chromatogr. Sci., 1970, 8, 2, 95-102, https://doi.org/10.1093/chromsci/8.2.95 . [all data]

Antheaume and Guiochon, 1965
Antheaume, J.; Guiochon, G., Application de la chromatographie en phase gazeuse à l'étude de la composition des fractions moyennes d'un brut pétrolier, Bull. Soc. Chim. Fr., 1965, 2, 298-307. [all data]


Notes

Go To: Top, Kovats' RI, non-polar column, isothermal, References


Copyright for NIST Standard Reference Data is governed by the Standard Reference Data Act.