Trihydroxy boroxine


Gas Phase Heat Capacity (Shomate Equation)

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Cp° = A + B*t + C*t2 + D*t3 + E/t2
H° − H°298.15= A*t + B*t2/2 + C*t3/3 + D*t4/4 − E/t + F − H
S° = A*ln(t) + B*t + C*t2/2 + D*t3/3 − E/(2*t2) + G
    Cp = heat capacity (J/mol*K)
    H° = standard enthalpy (kJ/mol)
    S° = standard entropy (J/mol*K)
    t = temperature (K) / 1000.

View plot Requires a JavaScript / HTML 5 canvas capable browser.

Temperature (K) 298. to 1200.1200. to 6000.
A 64.38590255.4930
B 414.761213.84076
C -339.3575-2.617357
D 102.77790.172356
E -2.087817-28.08979
F -2313.765-2416.867
G 304.2157558.0954
H -2271.916-2271.916
ReferenceChase, 1998Chase, 1998
Comment Data last reviewed in December, 1964 Data last reviewed in December, 1964
Temperature
(K)
Cp
(J/mol*K)
S°
(J/mol*K)
-(G° - H°298.15)/T
(J/mol*K)
H° - H°298.15
(kJ/mol)
298.137.1347.5347.6-0.03
300.137.8348.4347.60.24
400.169.5392.7353.415.72
500.191.4433.0365.333.83
600.207.5469.4379.753.82
700.219.4502.3394.975.19
800.228.4532.2410.297.60
900.235.1559.5425.3120.8
1000.240.5584.6440.0144.6
1100.245.1607.7454.2168.9
1200.249.6629.3467.9193.6
Temperature
(K)
Cp
(J/mol*K)
S°
(J/mol*K)
-(G° - H°298.15)/T
(J/mol*K)
H° - H°298.15
(kJ/mol)
1200.249.1629.3467.9193.6
1300.252.8649.3481.1218.7
1400.255.9668.2493.8244.1
1500.258.5685.9506.0269.9
1600.260.7702.7517.8295.8
1700.262.6718.6529.2322.0
1800.264.3733.6540.1348.3
1900.265.7747.9550.7374.8
2000.267.1761.6560.9401.5
2100.268.2774.7570.7428.2
2200.269.3787.2580.3455.1
2300.270.3799.2589.6482.1
2400.271.1810.7598.5509.2
2500.271.9821.8607.2536.3
2600.272.7832.4615.7563.6
2700.273.3842.8623.9590.9
2800.273.9852.7631.9618.2
2900.274.5862.3639.7645.6
3000.275.0871.6647.3673.1
3100.275.5880.7654.7700.6
3200.275.9889.4661.9728.2
3300.276.3897.9668.9755.8
3400.276.6906.2675.7783.5
3500.277.0914.2682.4811.1
3600.277.3922.0689.0838.8
3700.277.6929.6695.4866.6
3800.277.8937.0701.6894.4
3900.278.0944.2707.8922.1
4000.278.3951.3713.8950.0
4100.278.5958.1719.6977.8
4200.278.6964.8725.41006.
4300.278.8971.4731.11034.
4400.279.0977.8736.61061.
4500.279.1984.1742.01089.
4600.279.2990.2747.31117.
4700.279.4996.2752.61145.
4800.279.51002.757.71173.
4900.279.61008.762.81201.
5000.279.71014.767.71229.
5100.279.81019.772.61257.
5200.279.91024.777.41285.
5300.280.01030.782.11313.
5400.280.11035.786.71341.
5500.280.21040.791.31369.
5600.280.31045.795.81397.
5700.280.41050.800.21425.
5800.280.51055.804.61453.
5900.280.61060.808.81481.
6000.280.81065.813.11509.

References

Go To: Top, Gas Phase Heat Capacity (Shomate Equation), Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Chase, 1998
Chase, M.W., Jr., NIST-JANAF Themochemical Tables, Fourth Edition, J. Phys. Chem. Ref. Data, Monograph 9, 1998, 1-1951. [all data]


Notes

Go To: Top, Gas Phase Heat Capacity (Shomate Equation), References


Copyright for NIST Standard Reference Data is governed by the Standard Reference Data Act.