Cp° = A + B*t + C*t2 + D*t3 + E/t2
H° − H°298.15= A*t + B*t2/2 + C*t3/3 + D*t4/4 − E/t + F − H
S° = A*ln(t) + B*t + C*t2/2 + D*t3/3 − E/(2*t2) + G
    Cp = heat capacity (J/mol*K)
    H° = standard enthalpy (kJ/mol)
    S° = standard entropy (J/mol*K)
    t = temperature (K) / 1000.

View plot Requires a JavaScript / HTML 5 canvas capable browser.

Temperature (K) 3800. to 6000.
A 37.81846
B -0.978851
C 0.856092
D -0.084874
E -0.330890
F 358.4194
G 296.4808
H 370.7673
ReferenceChase, 1998
Comment Data last reviewed in September, 1977
Temperature
(K)
Cp
(J/mol*K)

(J/mol*K)
-(G° - H°298.15)/T
(J/mol*K)
H° - H°298.15
(kJ/mol)
3800.41.78347.9312.2135.6
3900.41.97349.0313.1139.8
4000.42.15350.0314.0144.0
4100.42.33351.1314.9148.2
4200.42.50352.1315.8152.5
4300.42.67353.1316.7156.7
4400.42.84354.1317.5161.0
4500.43.00355.1318.3165.3
4600.43.15356.0319.1169.6
4700.43.30356.9319.9173.9
4800.43.44357.8320.7178.3
4900.43.58358.7321.5182.6
5000.43.70359.6322.2187.0
5100.43.82360.5323.0191.4
5200.43.93361.3323.7195.7
5300.44.03362.2324.4200.1
5400.44.12363.0325.1204.6
5500.44.20363.8325.8209.0
5600.44.27364.6326.5213.4
5700.44.33365.4327.2217.8
5800.44.37366.2327.8222.3
5900.44.40366.9328.5226.7
6000.44.42367.7329.1231.1

References

Go To: Top, Gas Phase Heat Capacity (Shomate Equation), Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Chase, 1998
Chase, M.W., Jr., NIST-JANAF Themochemical Tables, Fourth Edition, J. Phys. Chem. Ref. Data, Monograph 9, 1998, 1-1951. [all data]


Notes

Go To: Top, Gas Phase Heat Capacity (Shomate Equation), References