Carbamic acid, phenyl-, 1-methylethyl ester

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Gas Chromatography

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Kovats' RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillaryOV-1160.1438.Erdmann, Rochholz, et al., 1992 
CapillaryOV-1190.1456.Erdmann, Rochholz, et al., 1992 
CapillaryOV-1220.1477.Erdmann, Rochholz, et al., 1992 
PackedSE-30140.1431.Gerqasimenko and Voskoboinikov, 1987Column length: 1. m
PackedSE-30140.1432.Gerqasimenko and Voskoboinikov, 1987Column length: 1. m
PackedSE-30160.1434.Gerqasimenko and Voskoboinikov, 1987Column length: 1. m
PackedSE-30160.1437.Gudovicheva and Boitsov, 1985Column length: 100. m

Kovats' RI, polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
PackedPEG 4000160.2000.Gudovicheva and Boitsov, 1985N2, Inerton AW (0.16-0.20 mm); Column length: 1. m

Van Den Dool and Kratz RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillarySLB-5MS1459.Mondello, Casilli, et al., 200730. m/0.25 mm/0.25 μm, He, 2. K/min; Tstart: 70. C; Tend: 300. C
CapillarySLB-5MS1462.Mondello, Casilli, et al., 200730. m/0.25 mm/0.25 μm, He, 2. K/min; Tstart: 70. C; Tend: 300. C

Normal alkane RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
PackedSE-30164.1423.Singlair, Macho, et al., 1989Nitrogen, Chromaton N AW DMCS; Column length: 2.5 m
PackedSE-30182.1449.Singlair, Macho, et al., 1989Nitrogen, Chromaton N AW DMCS; Column length: 2.5 m
PackedSE-30200.1453.Singlair, Macho, et al., 1989Nitrogen, Chromaton N AW DMCS; Column length: 2.5 m

References

Go To: Top, Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Erdmann, Rochholz, et al., 1992
Erdmann, F.; Rochholz, G.; Schütz, H., Retention-indices on OV-1 of approximately 170 commonly used pesticides, Mikrochim. Acta, 1992, 106, 3-6, 219-226, https://doi.org/10.1007/BF01242093 . [all data]

Gerqasimenko and Voskoboinikov, 1987
Gerqasimenko, V.A.; Voskoboinikov, V.V., Thermostability and gas chromatographic retention of substituted alkylarlcarbmates, Zh. Anal. Khim., 1987, 62, 11, 2043-2047. [all data]

Gudovicheva and Boitsov, 1985
Gudovicheva, N.N.; Boitsov, E.N., Gas-liquid chromatography of secondary carbamates, Zh. Anal. Khim., 1985, 40, 8, 1521-1524. [all data]

Mondello, Casilli, et al., 2007
Mondello, L.; Casilli, A.; Tranchida, P.Q.; Presti, M.L.; Dugo, P.; Dugo, G., Comprehensive gas chromatography coupled to mass spectrometry for the separation of pesticides in a very complex matrix, Anal. Bioanal. Chem., 2007, 389, 6, 1755-1763, https://doi.org/10.1007/s00216-007-1412-y . [all data]

Singlair, Macho, et al., 1989
Singlair, M.; Macho, V.; Terlandova, J., Fas chromatography of alkyl N-phenylcarbamates, Chem. Papers, 1989, 43, 4, 519-525. [all data]


Notes

Go To: Top, Gas Chromatography, References