Benzoic acid, 2-hydroxy-, ethyl ester

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Normal alkane RI, polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase FFAPFFAPDB-Wax EtrFFAPDB-Wax
Column length (m) 30.30.30.30.60.
Carrier gas NitrogenN2HeH2H2
Substrate      
Column diameter (mm) 0.320.320.250.320.32
Phase thickness (μm) 0.500.50.250.250.25
Tstart (C) 35.35.40.40.60.
Tend (C) 250.320.220.240.220.
Heat rate (K/min) 4.4.2.3.3.
Initial hold (min) 5.5.1.5. 
Final hold (min) 45.45.10.  
I 1832.1832.1837.1791.1786.
ReferenceBudryn, Nebesny, et al., 2011Nebesny, Budryn, et al., 2007Perestrelo, Fernandes, et al., 2006Ducruet, Fournier, et al., 2001Werkhoff, Güntert, et al., 1998
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillary
Active phase DB-WaxTC-Wax
Column length (m) 60.60.
Carrier gas He 
Substrate   
Column diameter (mm) 0.320.25
Phase thickness (μm) 0.25 
Tstart (C) 60.80.
Tend (C) 220.240.
Heat rate (K/min) 3.3.
Initial hold (min)  5.
Final hold (min)   
I 1786.1820.
ReferenceWerkhoff and Güntert, 1997Shuichi, Masazumi, et al., 1996
Comment MSDC-RI MSDC-RI

References

Go To: Top, Normal alkane RI, polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Budryn, Nebesny, et al., 2011
Budryn, G.; Nebesny, E.; Kula, J.; Majda, T.; Krysiak, W., HS-SPME/GC/MS Profiles of convectively and microwave roasted Ivory Coast Robusta coffee brews, Czech. J. Food Sci., 2011, 29, 2, 151-160. [all data]

Nebesny, Budryn, et al., 2007
Nebesny, E.; Budryn, G.; Kula, J.; Majda, T., The effect of roasting method on headspace composition of robusta coffee bean aroma, Eur. Food Res. Technol., 2007, 225, 1, 9-19, https://doi.org/10.1007/s00217-006-0375-0 . [all data]

Perestrelo, Fernandes, et al., 2006
Perestrelo, R.; Fernandes, A.; Albuquerque, F.F.; Marques, J.C.; Camara, J.S., Analytical characterization of the aroma of Tinta Negra Mole red wine: Identification of the main odorants compounds, Anal. Chim. Acta., 2006, 563, 1-2, 154-164, https://doi.org/10.1016/j.aca.2005.10.023 . [all data]

Ducruet, Fournier, et al., 2001
Ducruet, V.; Fournier, N.; Saillard, P.; Feigenbaum, A.; Guichard, E., Influence of packaging on the aroma stability of strawberry syrup during shelf life, J. Agric. Food Chem., 2001, 49, 5, 2290-2297, https://doi.org/10.1021/jf0012796 . [all data]

Werkhoff, Güntert, et al., 1998
Werkhoff, P.; Güntert, M.; Krammer, G.; Sommer, H.; Kaulen, J., Vacuum headspace method in aroma research: flavor chemistry of yellow passion fruits, J. Agric. Food Chem., 1998, 46, 3, 1076-1093, https://doi.org/10.1021/jf970655s . [all data]

Werkhoff and Güntert, 1997
Werkhoff, P.; Güntert, M., Identification of some ester compounds in bourbon vanilla beans, Lebensm. Wiss. Technol., 1997, 30, 4, 429-431, https://doi.org/10.1006/fstl.1996.0194 . [all data]

Shuichi, Masazumi, et al., 1996
Shuichi, H.; Masazumi, N.; Hiromu, K.; Kiyoshi, F., Comparison of volatile compounds berween the crude drugs, Onji-tsutsu and Onji-niki, Nippon nogei kagaku kaishi, 1996, 70, 2, 151-160. [all data]


Notes

Go To: Top, Normal alkane RI, polar column, temperature ramp, References