Propyl sulfide

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryPacked
Active phase DB-5DB-5DB-5DB-5Apiezon M
Column length (m) 30.30.30.30.2.1
Carrier gas     He or N2
Substrate     Chromosorb W, AW-DMCS
Column diameter (mm) 0.250.250.250.25 
Phase thickness (μm) 0.10.10.10.1 
Temperature (C) 100.120.60.80.130.
I 891.2896.7884.8887.4888.
ReferenceMiller and Bruno, 2003Miller and Bruno, 2003Miller and Bruno, 2003Miller and Bruno, 2003Garbuzov, Misharina, et al., 1985
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPackedPackedCapillaryCapillary
Active phase SE-30Apiezon MApiezon MApiezon LSqualane
Column length (m) 2.2.12.1  
Carrier gas  N2N2  
Substrate Chromosorb W AW (80-100 mesh)Chromosorb WChromosorb W  
Column diameter (mm)      
Phase thickness (μm)      
Temperature (C) 110.130.130.120.120.
I 887.888.888.890.882.
ReferenceMöckel and Zolg, 1977Golovnya, Garbuzov, et al., 1976Golovnya and Garbuzov, 1974Agr, Tesaric, et al., 1973Agr, Tesaric, et al., 1973
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase SqualaneSqualaneSqualaneApiezon LE-301
Column length (m)  50.50.100. 
Carrier gas  N2N2N2 
Substrate  Celite 545Celite 545  
Column diameter (mm)  0.30.30.3 
Phase thickness (μm)      
Temperature (C) 86.120.86.120.110.
I 878.882.878.890.877.
ReferenceAgr, Tesaric, et al., 1973Agrawal, Tesarík, et al., 1972Agrawal, Tesarík, et al., 1972Agrawal, Tesarík, et al., 1972Kudryavtseva, Fatalieva, et al., 1972
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPackedPackedPackedPacked
Active phase DC-200DC-200SE-30SE-30Apiezon L
Column length (m) 1.51.51.51.5 
Carrier gas      
Substrate      
Column diameter (mm)      
Phase thickness (μm)      
Temperature (C) 120.60.130.60.130.
I 888.879.888.878.894.
ReferenceGolovnya and Arsen'ev, 1970Golovnya and Arsen'ev, 1970Golovnya and Arsen'ev, 1970Golovnya and Arsen'ev, 1970Martinu and Janák, 1970
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Miller and Bruno, 2003
Miller, K.E.; Bruno, T.J., Isothermal Kováts retention indices of sulfur compounds on a poly(5% diphenyl-95% dimethylsiloxane) stationary phase, J. Chromatogr. A, 2003, 1007, 1-2, 117-125, https://doi.org/10.1016/S0021-9673(03)00958-0 . [all data]

Garbuzov, Misharina, et al., 1985
Garbuzov, V.G.; Misharina, T.A.; Aerov, A.F.; Golovnya, R.V., Gas chromatographic retention indices for sulphur(II)-containing organic substances, J. Anal. Chem. USSR (Engl. Transl.), 1985, 40, 4, 576-586. [all data]

Möckel and Zolg, 1977
Möckel, H.J.; Zolg, M., Retentionsindices n-aliphatischer Schwefelverbindungen, Z. Anal. Chem., 1977, 285, 1, 45-46, https://doi.org/10.1007/BF00446017 . [all data]

Golovnya, Garbuzov, et al., 1976
Golovnya, R.V.; Garbuzov, V.G.; Misharina, T.A., Gas chromatographic characteristics of sulfur compounds. 2. Normal sulfides, Izv. Akad. Nauk Kaz. SSR Ser. Khim., 1976, 10, 2266-2270. [all data]

Golovnya and Garbuzov, 1974
Golovnya, R.V.; Garbuzov, V.G., Effect of heteroatom in aliphatic sulfur- and oxygen-containing compounds on the values of the retention indices in gas chromatography, Izv. Akad. Nauk SSSR Ser. Khim., 1974, 7, 1519-1521. [all data]

Agr, Tesaric, et al., 1973
Agr, X.X.; Tesaric, K.; Janak, J., Will be entered later, J. Chromatogr., 1973, 95, 207-215. [all data]

Agrawal, Tesarík, et al., 1972
Agrawal, B.B.; Tesarík, K.; Janák, J., Gas chromatographic characterization of sulphur compounds in the 93-162° gasoline cut from Romashkino crude oil using Kováts retention indices, J. Chromatogr., 1972, 65, 1, 207-215, https://doi.org/10.1016/S0021-9673(00)86933-2 . [all data]

Kudryavtseva, Fatalieva, et al., 1972
Kudryavtseva, N.A.; Fatalieva, A.A.; Lulova, N.I.; Vinogradova, I.E., Methods of assessing fuel and oil quality. Use of gas chromatography to identify components of decomposition products from Sul'fol antiscuff additive, Chem. Technol. Fuels Oils (Engl. Transl.), 1972, 8, 10, 786-790, https://doi.org/10.1007/BF00717079 . [all data]

Golovnya and Arsen'ev, 1970
Golovnya, R.V.; Arsen'ev, Y.N., Gas-chromatographic method for the analysis of n-mercaptans and symmetrical n-sulfides and n-disulfides, Bull. Acad. Sci. USSR, Div. Chem. Sci. (Engl. Transl.), 1970, 6, 4, 1316-1318, https://doi.org/10.1007/BF00852683 . [all data]

Martinu and Janák, 1970
Martinu, V.; Janák, J., Gas-liquid chromatographic retention data of some aliphatic and alicyclic sulphides, J. Chromatogr., 1970, 52, 69-75, https://doi.org/10.1016/S0021-9673(01)96545-8 . [all data]


Notes

Go To: Top, Kovats' RI, non-polar column, isothermal, References