2-Octanone
- Formula: C8H16O
- Molecular weight: 128.2120
- IUPAC Standard InChIKey: ZPVFWPFBNIEHGJ-UHFFFAOYSA-N
- CAS Registry Number: 111-13-7
- Chemical structure:
This structure is also available as a 2d Mol file or as a computed 3d SD file
View 3d structure (requires JavaScript / HTML 5) - Other names: n-Hexyl methyl ketone; Hexyl methyl ketone; Methyl hexyl ketone; Methyl n-hexyl ketone; Octan-2-one; n-C6H13COCH3; Octanone-2
- Permanent link for this species. Use this link for bookmarking this species for future reference.
- Information on this page:
- Other data available:
- Data at other public NIST sites:
- Options:
Data at NIST subscription sites:
NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.
Normal alkane RI, polar column, custom temperature program
Go To: Top, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Column type | Capillary | Capillary | Capillary | Capillary | Capillary |
---|---|---|---|---|---|
Active phase | DB-Wax | DB-Wax | DB-Wax | Supelcowax-10 | Supelcowax-10 |
Column length (m) | 30. | 30. | 30. | 30. | 30. |
Carrier gas | Helium | Helium | Helium | He | He |
Substrate | |||||
Column diameter (mm) | 0.25 | 0.25 | 0.32 | 0.25 | 0.25 |
Phase thickness (μm) | 0.25 | 0.25 | 0.25 | 0.25 | 0.25 |
Program | 40 0C (4 min) 2.5 0C/min -> 80 0C 5 0C/min -> 110 0C 10 0C/min -> 220 0C (5 min) | not specified | 50 0C 20 0C/min -> 80 0C 3 0C/min -> 230 0C | 40C(10min) => 2C/min => 200C(1min) => 2C/min => 250C (10min) | 40C(3min) => 4C/min => 75C => 8C/min => 250C(5min) |
I | 1285. | 1283. | 1275. | 1278. | 1292. |
Reference | Canuti, Conversano, et al., 2009 | Canuti, Conversano, et al., 2009 | Tao, Wenlai, et al., 2008 | Bosch-Fuste, Riu-Aumatell, et al., 2007 | Vichi, Guadayol, et al., 2007 |
Comment | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI |
Column type | Capillary | Capillary | Capillary | Capillary | Capillary |
---|---|---|---|---|---|
Active phase | Innowax FSC | Carbowax 20M | DB-Wax | Supelcowax-10 | Carbowax 20M |
Column length (m) | 60. | 30. | 30. | ||
Carrier gas | He | He | He | ||
Substrate | |||||
Column diameter (mm) | 0.25 | 0.25 | 0.32 | ||
Phase thickness (μm) | 0.25 | 0.25 | 0.25 | ||
Program | 60C(10min) => 4C/min >220C (10min) => 1C/min => 240C | not specified | 25C(8min) => 4C/min => 60C => 6C/min => 160C => 20C/min => 200C | 50C(2min) => 7C/min => 140C => 17.5C/min => 230C | not specified |
I | 1295. | 1285. | 1276. | 1304. | 1304. |
Reference | Baser, Özek, et al., 2006 | Vinogradov, 2004 | Caldentey, Daria Fumi, et al., 1998 | Chang, Seitz, et al., 1995 | Shibamoto, 1987 |
Comment | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI |
References
Go To: Top, Normal alkane RI, polar column, custom temperature program, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Canuti, Conversano, et al., 2009
Canuti, V.; Conversano, M.; Li Calzi, M.; Heymann, H.; Matthews, M.A.; Ebeler, S.E.,
Headspace solid-phase microextraction - gas chromatography - mass spectrometry for profiling free volatile compounds in Cabernet Sauvignon grapes and vines,
J. Chromatogr. A., 2009, 1216, 15, 3012-3022, https://doi.org/10.1016/j.chroma.2009.01.104
. [all data]
Tao, Wenlai, et al., 2008
Tao, L.; Wenlai, F.; Yan, X.,
Characterization of volatile and semi-volatile compounds in Chinese rica wines by headspace solid phase microextraction followed by gas chromatography - mass spectrometry,
J. Inst. Brew., 2008, 114, 2, 172-179, https://doi.org/10.1002/j.2050-0416.2008.tb00323.x
. [all data]
Bosch-Fuste, Riu-Aumatell, et al., 2007
Bosch-Fuste, J.; Riu-Aumatell, M.; Guadayol, J.M.; Caixach, J.; Lopez-Tamames, E.; Buxaderas, S.,
Volatile profiles of sparkling wines obtained by three extraction methods and gas chromatography-mass spectrometry (GC-MS) analysis,
Food Chem., 2007, 105, 1, 428-435, https://doi.org/10.1016/j.foodchem.2006.12.053
. [all data]
Vichi, Guadayol, et al., 2007
Vichi, S.; Guadayol, J.M.; Caixach, J.; López-Tamames, E.; Buxaderas, S.,
Analytical, Nutritional, and Clinical Methods. Comparative study of different extraction techniques for the analysis of virgin olive oil aroma,
Food Chem., 2007, 105, 3, 1171-1178, https://doi.org/10.1016/j.foodchem.2007.02.018
. [all data]
Baser, Özek, et al., 2006
Baser, K.H.C.; Özek, G.; Özek, T.; Duran, A.; Duman, H.,
Composition of the essential oils of Rhabdosciadium oligocarpum (Post ex Boiss.) Hedge et Lamond and Rhabdosciadium microcalycinum Hand.-Mazz.,
Flavour Fragr. J., 2006, 21, 4, 650-655, https://doi.org/10.1002/ffj.1639
. [all data]
Vinogradov, 2004
Vinogradov, B.A.,
Production, composition, properties and application of essential oils, 2004, retrieved from http://viness.narod.ru. [all data]
Caldentey, Daria Fumi, et al., 1998
Caldentey, P.; Daria Fumi, M.; Mazzoleni, V.; Careri, M.,
Volatile compounds produced by microorganisms isolated from cork,
Flavour Fragr. J., 1998, 13, 3, 185-188, https://doi.org/10.1002/(SICI)1099-1026(199805/06)13:3<185::AID-FFJ723>3.0.CO;2-W
. [all data]
Chang, Seitz, et al., 1995
Chang, C.-Y.; Seitz, L.M.; Chambers, E., IV,
Volatile Flavor Components of Breads Made from Hard Red Winter Wheat and Hard White Winter Wheat,
Cereal Chem., 1995, 72, 3, 237-242. [all data]
Shibamoto, 1987
Shibamoto, T.,
Retention Indices in Essential Oil Analysis
in Capillary Gas Chromatography in Essential Oil Analysis, Sandra, P.; Bicchi, C., ed(s)., Hutchig Verlag, Heidelberg, New York, 1987, 259-274. [all data]
Notes
Go To: Top, Normal alkane RI, polar column, custom temperature program, References
- Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.