Benzene, nitro-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Normal alkane RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillary
Active phase OV-101OV-101SE-54
Column length (m) 54.54.25.
Carrier gas HeliumHeliumHe
Substrate    
Column diameter (mm) 0.260.260.32
Phase thickness (μm)    
Tstart (C) 75.75.50.
Tend (C) 220.220.250.
Heat rate (K/min) 6.6.8.
Initial hold (min) 0.0.2.
Final hold (min) 0.0.12.
I 1059.1062.1084.
ReferenceZenkevich and Tsibulskaya, 1989Zenkevich and Tsibulskaya, 1989Harland, Cumming, et al., 1986
Comment MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Normal alkane RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Zenkevich and Tsibulskaya, 1989
Zenkevich, I.G.; Tsibulskaya, I.A., Influence of Relative Amounts of Mixture Components on the Precision of Measurements of Gas Chromatographic Retention Indices, Zh. Anal. Khim. (Rus.), 1989, 44, 1, 90-96. [all data]

Harland, Cumming, et al., 1986
Harland, B.J.; Cumming, R.I.; Gillings, E., The Kovats indexes of some organic micropollutants on an SE54 capillary column, EUR, I Org. Micropollut. Aquat. Environ., 1986, EUR 10388, 123-127. [all data]


Notes

Go To: Top, Normal alkane RI, non-polar column, temperature ramp, References