α-Methylstyrene

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Normal alkane RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase Petrocol DHOV-101BP-1Methyl SiliconeOV-101
Column length (m) 100.25.50.60.50.
Carrier gas HeliumN2He Helium
Substrate      
Column diameter (mm) 0.250.200.220.250.20
Phase thickness (μm) 0.50 0.750.250.50
Tstart (C) 20.60.50.40.30.
Tend (C) 220.240.200.220.100.
Heat rate (K/min) 15.4.5.5.1.
Initial hold (min) 15.  10.6.
Final hold (min) 30.    
I 969.965.972.965.23964.
ReferenceSupelco, 2012Zenkevich, 2001Health Safety Executive, 2000Baraldi, Rapparini, et al., 1999Orav, Kailas, et al., 1999
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillary
Active phase SP-2100OV-101
Column length (m) 30.54.
Carrier gas HeHelium
Substrate   
Column diameter (mm) 0.250.26
Phase thickness (μm)   
Tstart (C) 40.50.
Tend (C) 280.220.
Heat rate (K/min) 5.3.
Initial hold (min) 3.0.
Final hold (min)  0.
I 961.968.
ReferenceFischer and Kusch, 1993Mandelshtam, Kharicheva, et al., 1991
Comment MSDC-RI MSDC-RI

References

Go To: Top, Normal alkane RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Supelco, 2012
Supelco, CatalogNo. 24160-U, Petrocol DH Columns. Catalog No. 24160-U, 2012, retrieved from http://www.sigmaaldrich.com/etc/medialib/docs/Supelco/Datasheet/1/w97949.Par.0001.File.tmp/w97949.pdf. [all data]

Zenkevich, 2001
Zenkevich, I.G., Interpretation of Gas Chromatographic Retention Indices in estimation of Structures of Isomeric Products of Radical Chlorinating of Alkyl Arenes, Zh. Org. Khim., 2001, 37, 2, 283-293. [all data]

Health Safety Executive, 2000
Health Safety Executive, MDHS 96 Volatile organic compounds in air - Laboratory method using pumed solid sorbent tubes, solvent desorption and gas chromatography in Methods for the Determination of Hazardous Substances (MDHS) guidance, Crown, Colegate, Norwich, 2000, 1-24, retrieved from http://www.hse.gov.uk/pubns/mdhs/pdfs/mdhs96.pdf. [all data]

Baraldi, Rapparini, et al., 1999
Baraldi, R.; Rapparini, F.; Rossi, F.; Latella, A.; Ciccioli, P., Volatile organic compound emissions from flowers of the most occurring and economically important species of fruit trees, Phys. Chem. Earth, 1999, 24, 6, 729-732, https://doi.org/10.1016/S1464-1909(99)00073-8 . [all data]

Orav, Kailas, et al., 1999
Orav, A.; Kailas, T.; Muurisepp, M.; Kann, J., Composition of the oil from waste tires. 1. Fraction boiling at yp to 160 0C, Proc. Estonian Acad. Sci. Chem., 1999, 48, 1, 30-39. [all data]

Fischer and Kusch, 1993
Fischer, G.W.; Kusch, P., An Automated Curie-Point Pyrolysis-High Resolution Gas Chromatography System, LC-GC Int., 1993, 6, 12, 760-763. [all data]

Mandelshtam, Kharicheva, et al., 1991
Mandelshtam, T.V.; Kharicheva, E.M.; Gorobets, I.A.; Zenkevich, I.G.; Kostikov, R.R.; Porokhovnikova, E.B., Synthesis and Chromato Mass Spectrometric Investigation of alpha-Alkoxystyrenes, Zh. Org. Khim. (Rus.), 1991, 27, 4, 684-690. [all data]


Notes

Go To: Top, Normal alkane RI, non-polar column, temperature ramp, References