Benzene, tert-butyl-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Normal alkane RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase Polydimethyl siloxane: CP-Sil 5 CBPetrocol DHDB-1OV-1OV-101
Column length (m) 60.100.30. 50.
Carrier gas HeliumHeliumNitrogen Helium
Substrate      
Column diameter (mm) 0.250.250.32 0.20
Phase thickness (μm) 1.00.500.25 0.50
Tstart (C) 45.20.100.50.30.
Tend (C) 210.220.200.160.100.
Heat rate (K/min) 3.615.5.2.1.
Initial hold (min) 1.4515.  6.
Final hold (min) 2.7230.   
I 977.984.984.984.975.
ReferenceBramston-Cook, 2013Supelco, 2012Zenkevich, Ukolov, et al., 2011Orav, Kailas, et al., 1999Orav, Kailas, et al., 1999, 2
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase DB-1OV-1OV-1CP Sil 5 CBOV-101
Column length (m) 60.50.50.25.54.
Carrier gas HeH2H2HeHelium
Substrate      
Column diameter (mm) 0.320.320.320.320.26
Phase thickness (μm) 1.20.520.520.45 
Tstart (C) 30.30.35.0.50.
Tend (C) 240.  320.240.
Heat rate (K/min) 3.1.2.3.5.
Initial hold (min) 10.  5.0.
Final hold (min)    10.0.
I 994.971.975.975.980.
ReferenceCiccioli, Cecinato, et al., 1992Guan, Zheng, et al., 1992Guan, Zheng, et al., 1992Hartgers, Damste, et al., 1992Zenkevich and Ventura, 1991
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type Capillary
Active phase SE-30
Column length (m) 50.
Carrier gas He
Substrate  
Column diameter (mm) 0.5
Phase thickness (μm)  
Tstart (C) 40.
Tend (C) 170.
Heat rate (K/min) 3.
Initial hold (min) 3.
Final hold (min)  
I 961.
ReferenceHeydanek and McGorrin, 1981
Comment MSDC-RI

References

Go To: Top, Normal alkane RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Bramston-Cook, 2013
Bramston-Cook, R., Kovats indices for C2-C13 hydrocarbons and selected oxygenated/halocarbons with 100 % dimethylpolysiloxane columns, 2013, retrieved from http://lotusinstruments.com/monographs/List .... [all data]

Supelco, 2012
Supelco, CatalogNo. 24160-U, Petrocol DH Columns. Catalog No. 24160-U, 2012, retrieved from http://www.sigmaaldrich.com/etc/medialib/docs/Supelco/Datasheet/1/w97949.Par.0001.File.tmp/w97949.pdf. [all data]

Zenkevich, Ukolov, et al., 2011
Zenkevich, I.G.; Ukolov, A.I.; Kushakova, A.S.; Gustyleva, L.K., Identification of isomeric alkylarenes with the use of additive relations for the evaluation of gas-chromatographic retention indices, Rus. J. Anal. Chem., 2011, 66, 12, 1165-1172, https://doi.org/10.1134/S1061934811120136 . [all data]

Orav, Kailas, et al., 1999
Orav, A.; Kailas, T.; Muurisepp, M.; Kann, J., Composition of the oil from waste tires. 2. Fraction boiling at 160-180 0C, Proc. Estonian Acad. Sci. Chem., 1999, 48, 3, 136-140. [all data]

Orav, Kailas, et al., 1999, 2
Orav, A.; Kailas, T.; Muurisepp, M.; Kann, J., Composition of the oil from waste tires. 1. Fraction boiling at yp to 160 0C, Proc. Estonian Acad. Sci. Chem., 1999, 48, 1, 30-39. [all data]

Ciccioli, Cecinato, et al., 1992
Ciccioli, P.; Cecinato, A.; Brancaleoni, E.; Frattoni, M.; Liberti, A., Use of carbon adsorption traps combined with high resolution gas chromatography - mass spectrometry for the analysis of polar and non-polar C4-C14 hydrocarbons involved in photochemical smog formation, J. Hi. Res. Chromatogr., 1992, 15, 2, 75-84, https://doi.org/10.1002/jhrc.1240150205 . [all data]

Guan, Zheng, et al., 1992
Guan, Y.; Zheng, P.; Zhou, L., Prediction, optimization of separation, and identification of unknown compounds in capillary gas chromatography, J. Hi. Res. Chromatogr., 1992, 15, 1, 18-23, https://doi.org/10.1002/jhrc.1240150106 . [all data]

Hartgers, Damste, et al., 1992
Hartgers, W.A.; Damste, J.S.S.; de Leeuw, J.W., Identification of C2-C4 alkylated benzenes in flash pyrolysates of kerogens, coals and asphaltenes, J. Chromatogr., 1992, 606, 2, 211-220, https://doi.org/10.1016/0021-9673(92)87027-6 . [all data]

Zenkevich and Ventura, 1991
Zenkevich, I.G.; Ventura, K., Gas Chromatographic Identification of Volatile Products of Thermal Degradation of Bitumen, Zh. Prikl. Khim. (Rus.), 1991, 9, 1974-1979. [all data]

Heydanek and McGorrin, 1981
Heydanek, M.G.; McGorrin, R.J., Gas chromatography-mass spectroscopy investigations on the flavor chemistry of oat groats, J. Agric. Food Chem., 1981, 29, 5, 950-954, https://doi.org/10.1021/jf00107a016 . [all data]


Notes

Go To: Top, Normal alkane RI, non-polar column, temperature ramp, References