Pentanoic acid, 2-methyl-
- Formula: C6H12O2
- Molecular weight: 116.1583
- IUPAC Standard InChIKey: OVBFMEVBMNZIBR-UHFFFAOYSA-N
- CAS Registry Number: 97-61-0
- Chemical structure:
This structure is also available as a 2d Mol file or as a computed 3d SD file
The 3d structure may be viewed using Java or Javascript. - Species with the same structure:
- Other names: Valeric acid, 2-methyl-; α-Methylvaleric acid; Methylpropylacetic acid; 2-Methylpentanoic acid; 2-Methylvaleric acid; 2-Pentanecarboxylic acid; n-C3H7CH(CH3)COOH; 2-Methyl-n-valeric acid; Kyselina 2-methylvalerova
- Information on this page:
- Other data available:
- Data at other public NIST sites:
- Options:
Data at NIST subscription sites:
NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.
Normal alkane RI, polar column, temperature ramp
Go To: Top, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Column type | Capillary | Capillary | Capillary | Capillary | Capillary |
---|---|---|---|---|---|
Active phase | DB-Wax | ZB-Wax | ZB-Wax | TC-Wax | DB-Wax |
Column length (m) | 30. | 30. | 30. | 60. | 60. |
Carrier gas | He | Helium | He | He | He |
Substrate | |||||
Column diameter (mm) | 0.32 | 0.32 | 0.32 | 0.25 | 0.25 |
Phase thickness (μm) | 0.25 | 0.25 | 0.25 | 0.25 | |
Tstart (C) | 40. | 40. | 40. | 40. | 60. |
Tend (C) | 230. | 250. | 250. | 230. | 180. |
Heat rate (K/min) | 4. | 5. | 5. | 3. | 2. |
Initial hold (min) | 2. | 2. | 2. | 10. | |
Final hold (min) | 15. | 5. | 10. | 10. | |
I | 1764. | 1755. | 1755. | 1769. | 1770. |
Reference | Fan and Qian, 2006 | N/A | Wu, Krings, et al., 2005 | Suhardi, Suzuki, et al., 2002 | Sekiwa, Kubota, et al., 1997 |
Comment | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI |
References
Go To: Top, Normal alkane RI, polar column, temperature ramp, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Fan and Qian, 2006
Fan, W.; Qian, M.C.,
Characterization of Aroma Compounds of Chinese Wuliangye and Jiannanchun Liquors by Aroma Extract Dilution Analysis,
J. Agric. Food Chem., 2006, 54, 7, 2695-2704, https://doi.org/10.1021/jf052635t
. [all data]
Wu, Krings, et al., 2005
Wu, S.; Krings, U.; Zorn, H.; Berger, R.G.,
Volatile compounds from the fruiting bodies of beefsteak fungus Fistulina hepatica (Schaeffer: Fr.) Fr.,
Food Chem., 2005, 92, 2, 221-226, https://doi.org/10.1016/j.foodchem.2004.07.013
. [all data]
Suhardi, Suzuki, et al., 2002
Suhardi, S.; Suzuki, M.; Yoshida, K.; Muto, T.; Fujita, A.; Watanbe, N.,
Changes in the volatile compounds and in the chemical and physical properties of snake fruit (Salacca edulis Reinw) Cv. Pondoh during maturation,
J. Agric. Food Chem., 2002, 50, 26, 7627-7633, https://doi.org/10.1021/jf020620e
. [all data]
Sekiwa, Kubota, et al., 1997
Sekiwa, Y.; Kubota, K.; Kobayashi, A.,
Characteristic flavor components in the brew of cooked clam (Meretrix lusoria) and the effect of storage on flavor formation,
J. Agric. Food Chem., 1997, 45, 3, 826-830, https://doi.org/10.1021/jf960433e
. [all data]
Notes
Go To: Top, Normal alkane RI, polar column, temperature ramp, References
- Symbols used in this document:
Tend Final temperature Tstart Initial temperature - Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.
- Customer support for NIST Standard Reference Data products.