3-Pentanone

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase OV-1HP-1HP-1HP-1HP-1
Column length (m)  50.50.50.50.
Carrier gas      
Substrate      
Column diameter (mm)  0.320.320.320.32
Phase thickness (μm)  1.051.051.051.05
Temperature (C) 333.110.30.50.70.
I 676.4676.91675.75675.42675.52
ReferenceHu, Lu, et al., 2006Héberger, Görgényi, et al., 2002Héberger, Görgényi, et al., 2002Héberger, Görgényi, et al., 2002Héberger, Görgényi, et al., 2002
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase HP-1HP-101HP-1HP-1HP-1
Column length (m) 50.50.50.50.50.
Carrier gas  H2N2N2N2
Substrate      
Column diameter (mm) 0.320.20.320.320.32
Phase thickness (μm) 1.050.21.051.051.05
Temperature (C) 90.60.110.50.70.
I 675.84677.74677.675.676.
ReferenceHéberger, Görgényi, et al., 2002Garay, 2000Héberger and Görgényi, 1999Héberger and Görgényi, 1999Héberger and Görgényi, 1999
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase HP-1SE-30SE-30SE-30SE-30
Column length (m) 50.25.25.25.25.
Carrier gas N2HeHeHeHe
Substrate      
Column diameter (mm) 0.320.320.320.320.32
Phase thickness (μm) 1.051.1.1.1.
Temperature (C) 90.100.110.80.90.
I 676.682.681.682.682.
ReferenceHéberger and Görgényi, 1999Golovnya, Syomina, et al., 1997Golovnya, Syomina, et al., 1997Golovnya, Syomina, et al., 1997Golovnya, Syomina, et al., 1997
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPackedPackedPackedCapillary
Active phase SqualaneApiezon LApiezon LApiezon LSqualane
Column length (m)     50.
Carrier gas H2    
Substrate  Celite 545Celite 545  
Column diameter (mm)     0.25
Phase thickness (μm)      
Temperature (C) 80.120.160.130.60.
I 640.658.665.651.638.
ReferenceFernández-Sánchez, García-Domínguez, et al., 1987Bogoslovsky, Anvaer, et al., 1978Bogoslovsky, Anvaer, et al., 1978Bogoslovsky, Anvaer, et al., 1978Ryba, 1976
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryPackedPacked
Active phase SqualaneApiezon LApiezon L
Column length (m) 50.2.252.25
Carrier gas    
Substrate  CeliteCelite
Column diameter (mm) 0.25  
Phase thickness (μm)    
Temperature (C) 60.130.70.
I 647.651.647.
ReferenceRyba, 1976Wehrli and Kováts, 1959Wehrli and Kováts, 1959
Comment MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Hu, Lu, et al., 2006
Hu, X.-F.; Lu, C.-H.; Yin, C.-S., Modeling Gas Chromatographic Retention Indices of Oxygen-containing Compounds by Novel Atom-type Topological Indices, Chinese Journal of Chemical Physics, 2006, 19, 3, 243-247, https://doi.org/10.1360/cjcp2006.19(3).243.5 . [all data]

Héberger, Görgényi, et al., 2002
Héberger, K.; Görgényi, M.; Kowalska, T., Temperature dependence of Kováts indices in gas chromatography revisited, J. Chromatogr. A, 2002, 973, 1-2, 135-142, https://doi.org/10.1016/S0021-9673(02)01198-6 . [all data]

Garay, 2000
Garay, F., Application of a flow-tunable, serially coupled gas chromatographic capillary column system for the analysis of complex mixtures, Chromatographia Sup., 2000, 51, 1, s108-s120, https://doi.org/10.1007/BF02492792 . [all data]

Héberger and Görgényi, 1999
Héberger, K.; Görgényi, M., Principal component analysis of Kováts indices for carbonyl compounds in capillary gas chromatography, J. Chromatogr., 1999, 845, 1-2, 21-31, https://doi.org/10.1016/S0021-9673(99)00323-4 . [all data]

Golovnya, Syomina, et al., 1997
Golovnya, R.V.; Syomina, L.A.; Samusenko, A.L., Temperature changes of sorption parameters of di-n-alkylketones and methylcyclohexanones in capillary gas chromatography, Russ. Chem. Bull. (Engl. Transl.), 1997, 46, 2, 314-318, https://doi.org/10.1007/BF02494370 . [all data]

Fernández-Sánchez, García-Domínguez, et al., 1987
Fernández-Sánchez, E.; García-Domínguez, J.A.; García-Muñoz, J.; Menéndez, V.; Molera, M.J., Prediction of gas chromatographic retention indices on binary mixed stationary phases, An. Quim., 1987, 83, 56-58. [all data]

Bogoslovsky, Anvaer, et al., 1978
Bogoslovsky, Yu.N.; Anvaer, B.I.; Vigdergauz, M.S., Chromatographic constants in gas chromatography (in Russian), Standards Publ. House, Moscow, 1978, 192. [all data]

Ryba, 1976
Ryba, M., Unlösliche Restfilme er stationären Flüssigkeit in gas-chromatographischen Glaskapillaren, Chromatographia, 1976, 9, 3, 105-112, https://doi.org/10.1007/BF02330376 . [all data]

Wehrli and Kováts, 1959
Wehrli, A.; Kováts, E., Gas-chromatographische Charakterisierung ogranischer Verbindungen. Teil 3: Berechnung der Retentionsindices aliphatischer, alicyclischer und aromatischer Verbindungen, Helv. Chim. Acta, 1959, 7, 7, 2709-2736, https://doi.org/10.1002/hlca.19590420745 . [all data]


Notes

Go To: Top, Kovats' RI, non-polar column, isothermal, References