Benzoic acid, methyl ester

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase SE-30SE-30SE-30SE-30SE-30
Column length (m) 40.25.25.25.25.
Carrier gas  N2N2N2N2
Substrate      
Column diameter (mm) 0.350.330.330.330.33
Phase thickness (μm) 0.35    
Temperature (C) 100.160.180.200.160.
I 1077.81067.1064.1063.1097.
ReferenceTudor, 1997Korhonen, 1986Korhonen, 1986Korhonen, 1986Korhonen and Lind, 1985
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryPackedPackedPacked
Active phase SE-30SE-30SE-30SE-30SE-30
Column length (m) 25.25.3.3.72.
Carrier gas N2N2Ar  
Substrate   Gas Chrom Q (80-100 mesh)Chromosorb W AW DMCSGaschrom Q
Column diameter (mm) 0.330.33   
Phase thickness (μm)      
Temperature (C) 180.200.150.200.150.
I 1100.1101.1090.1101.1095.
ReferenceKorhonen and Lind, 1985Korhonen and Lind, 1985Tiess, 1984Haken, Hartley, et al., 1983Winskowski, 1983
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPackedPackedPackedPacked
Active phase OV-1SE-30SE-30SE-30Apiezon L
Column length (m) 1.51.1.1.1.
Carrier gas  ArArArN2
Substrate GaschromChromosorb W AW DMCS HP (80-100 mesh)Chromosorb W AW DMCS HP (80-100 mesh)Chromosorb W AW DMCS HP (80-100 mesh)Celite
Column diameter (mm)      
Phase thickness (μm)      
Temperature (C) 150.100.120.140.180.
I 1078.1081.1087.1092.1109.
ReferenceFedoreev and Maksimov, 1977Pías and Gascó, 1975Pías and Gascó, 1975Pías and Gascó, 1975Vernon and Edwards, 1975
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type Packed
Active phase OV-101
Column length (m) 2.
Carrier gas  
Substrate Gas Chrom Q
Column diameter (mm)  
Phase thickness (μm)  
Temperature (C) 100.
I 1072.
ReferenceWest and Hall, 1975
Comment MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Tudor, 1997
Tudor, E., Temperature dependence of the retention index for perfumery compounds on a SE-30 glass capillary column. I. Linear equations, J. Chromatogr. A, 1997, 779, 1-2, 287-297, https://doi.org/10.1016/S0021-9673(97)00453-6 . [all data]

Korhonen, 1986
Korhonen, I.O.O., Gas-Liquid Chromatographic Analyses. XLV. Retention Behaviour of C1-C12 n-Alkyl Esters of Benzoic, 4-Nitrobenzoic and 3,5-Dinitrobenzoic Acids on SE-30 and OV-351 Capillary Columns, J. Chromatogr., 1986, 356, 285-299, https://doi.org/10.1016/S0021-9673(00)91489-4 . [all data]

Korhonen and Lind, 1985
Korhonen, I.O.O.; Lind, M.A., Gas-liquid chromatographic analyses. XXXV. Capillary column studies of C1-C12 n-alkyl esters of benzoic and monochlorobenzoic acids, J. Chromatogr., 1985, 322, 83-96, https://doi.org/10.1016/S0021-9673(01)97661-7 . [all data]

Tiess, 1984
Tiess, D., Gaschromatographische Retentionsindices von 125 leicht- bis mittelflüchtigen organischen Substanzen toxikologisch-analytischer Relevanz auf SE-30, Wiss. Z. Wilhelm-Pieck-Univ. Rostock Math. Naturwiss. Reihe, 1984, 33, 6-9. [all data]

Haken, Hartley, et al., 1983
Haken, J.K.; Hartley, H.N.T.; Srisukh, D., Retention increments of aromatic esters, Chromatographia, 1983, 17, 11, 589-596, https://doi.org/10.1007/BF02261941 . [all data]

Winskowski, 1983
Winskowski, J., Gaschromatographische Identifizierung von Stoffen anhand von Indexziffem und unterschiedlichen Detektoren, Chromatographia, 1983, 17, 3, 160-165, https://doi.org/10.1007/BF02271041 . [all data]

Fedoreev and Maksimov, 1977
Fedoreev, S.A.; Maksimov, O.B., The study of the composition of aromatic esters by gas-liquid chromatography, Solid Fuel Chem. (Engl. Transl.), 1977, 17-22. [all data]

Pías and Gascó, 1975
Pías, J.B.; Gascó, L., GC Retention Data of Alcohols and Benzoyl Derivatives of Alcohols, J. Chromatogr. - Chrom. Data, 1975, d14-d16. [all data]

Vernon and Edwards, 1975
Vernon, F.; Edwards, G.T., Gas-liquid chromatography on fluorinated stationary phases. II. Fluorinated compounds containing a functional group, J. Chromatogr., 1975, 114, 1, 87-93, https://doi.org/10.1016/S0021-9673(00)85245-0 . [all data]

West and Hall, 1975
West, S.D.; Hall, R.C., Substituent contributions to the Kováts retention indices of benzene derivatives, J. Chromatogr. Sci., 1975, 13, 5-11. [all data]


Notes

Go To: Top, Kovats' RI, non-polar column, isothermal, References