Isopulegol


Van Den Dool and Kratz RI, non-polar column, custom temperature program

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillary
Active phase 5 % Phenyl methyl siloxaneSE-52CP Sil 5 CBSE-52
Column length (m) 30.25. 60.
Carrier gas HeHe He
Substrate     
Column diameter (mm) 0.320.25 0.32
Phase thickness (μm) 0.150.25 0.40
Program 45C => 1C/min => 100C => 5C/min => 250C (10min)60C(8min) => 3C/min => 180C => 20C/min => 230Cnot specified45 C (6 min) 3 C/min -> 111 0C 2 C/min -> 160 C 3 C/min -> 300 C (15 min)
I 1150.1142.1145.1147.
ReferenceSacchetti, Maietti, et al., 2005Lorenzo, Dellacassa, et al., 2000Chanegriha, Baaliouamer, et al., 1998Mondello, Dugo, et al., 1995
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Van Den Dool and Kratz RI, non-polar column, custom temperature program, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Sacchetti, Maietti, et al., 2005
Sacchetti, G.; Maietti, S.; Muzzoli, M.; Scaglianti, M.; Manfredini, S.; Radice, M.; Bruni, R., Comparative evaluation of 11 essential oils of different origin as functional antioxidants, antiradicals and antimicrobials in foods, Food Chem., 2005, 91, 4, 621-632, https://doi.org/10.1016/j.foodchem.2004.06.031 . [all data]

Lorenzo, Dellacassa, et al., 2000
Lorenzo, D.; Dellacassa, E.; Atti-Serafini, L.; Santos, A.C.; Frizzo, C.; Paroul, N.; Moyna, P.; Mondello, L.; Dugo, G., Composition and stereoanalysis of Cymbopogon winterianus Jowitt oil from Southern Brazil, Flavour Fragr. J., 2000, 15, 3, 177-181, https://doi.org/10.1002/1099-1026(200005/06)15:3<177::AID-FFJ887>3.0.CO;2-M . [all data]

Chanegriha, Baaliouamer, et al., 1998
Chanegriha, N.; Baaliouamer, A.; Rolando, C., Polarity changes during capillary gas chromatographic and gas chromatographic-mass spectrometric analysis using serially coupled columns of different natures and temperature programming. Application to the identification of constituents of essential oils, J. Chromatogr. A, 1998, 819, 1-2, 61-65, https://doi.org/10.1016/S0021-9673(98)00449-X . [all data]

Mondello, Dugo, et al., 1995
Mondello, L.; Dugo, P.; Basile, A.; Dugo, G., Interactive use of linear retention indices, on polar and apolar columns, with a MS-library for reliable identification of complex mixtures, J. Microcolumn Sep., 1995, 7, 6, 581-591, https://doi.org/10.1002/mcs.1220070605 . [all data]


Notes

Go To: Top, Van Den Dool and Kratz RI, non-polar column, custom temperature program, References