Nonane, 2-methyl-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Normal alkane RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase Polydimethyl siloxane: CP-Sil 5 CBPetrocol DHVF-5 MSVF-5 MSPONA
Column length (m) 60.100.60.60.50.
Carrier gas HeliumHeliumHeliumHeliumNitrogen
Substrate      
Column diameter (mm) 0.250.250.320.320.20
Phase thickness (μm) 1.00.500.250.250.50
Tstart (C) 45.20.30.30.35.
Tend (C) 210.220.260.260.200.
Heat rate (K/min) 3.615.2.2.2.
Initial hold (min) 1.4515.  15.
Final hold (min) 2.7230.28.28.10.
I 966.969.964.968.966.
ReferenceBramston-Cook, 2013Supelco, 2012Leffingwell and Alford, 2011Leffingwell and Alford, 2011Zhang, Ding, et al., 2009
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase OV-1SPB-5HP-5MSDB-1OV-101
Column length (m) 100.60.30.30.50.
Carrier gas Helium He Helium
Substrate      
Column diameter (mm) 0.320.320.250.320.20
Phase thickness (μm) 0.251.0.250.250.50
Tstart (C) 30.40.50.60.30.
Tend (C) 310.230.280.320.100.
Heat rate (K/min) 5.3.5. 1.
Initial hold (min)  5.4. 6.
Final hold (min) 5.5.10.  
I 965.4965.970.966.963.
ReferenceKrkosova, Kubinec, et al., 2007Vasta, Ratel, et al., 2007Kim, El-Aty, et al., 2006Katritzky, Chen, et al., 2000Orav, Kailas, et al., 1999
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type Capillary
Active phase OV-1
Column length (m) 50.
Carrier gas He
Substrate  
Column diameter (mm) 0.2
Phase thickness (μm) 0.52
Tstart (C) 35.
Tend (C) 150.
Heat rate (K/min) 1.1
Initial hold (min) 10.
Final hold (min)  
I 965.0
ReferenceDurand, Boscher, et al., 1987
Comment MSDC-RI

References

Go To: Top, Normal alkane RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Bramston-Cook, 2013
Bramston-Cook, R., Kovats indices for C2-C13 hydrocarbons and selected oxygenated/halocarbons with 100 % dimethylpolysiloxane columns, 2013, retrieved from http://lotusinstruments.com/monographs/List .... [all data]

Supelco, 2012
Supelco, CatalogNo. 24160-U, Petrocol DH Columns. Catalog No. 24160-U, 2012, retrieved from http://www.sigmaaldrich.com/etc/medialib/docs/Supelco/Datasheet/1/w97949.Par.0001.File.tmp/w97949.pdf. [all data]

Leffingwell and Alford, 2011
Leffingwell, J.; Alford, E.D., Volatile constituents of the giant pufball mushroom (Calvatia gigantea), Leffingwell Rep., 2011, 4, 1-17. [all data]

Zhang, Ding, et al., 2009
Zhang, X.; Ding, L.; Sun, Z.; Song, L.; Sun, T., Study on quantitative structure-retention relationships for hydrocarbons in FCC gasoline, Chromatographia, 2009, 70, 3/4, 511-518, https://doi.org/10.1365/s10337-009-1174-0 . [all data]

Krkosova, Kubinec, et al., 2007
Krkosova, Z.; Kubinec, R.; Addova, G.; Jurdakova, H.; Blasko, J.; Ostrovsky, I.; Sojak, L., Gas chromatographic - mass spectrometric characterization of monomethylalkanes from fuel diesel, Petroleum Coal, 2007, 49, 3, 51-62. [all data]

Vasta, Ratel, et al., 2007
Vasta, V.; Ratel, J.; Engel, E., Mass Spectrometry Analysis of Volatile Compounds in Raw Meat for the Authentication of the Feeding Background of Farm Animals, J. Agric. Food Chem., 2007, 55, 12, 4630-4639, https://doi.org/10.1021/jf063432n . [all data]

Kim, El-Aty, et al., 2006
Kim, M.R.; El-Aty, A.M.A.; Choi, J.-H.; Lee, K.B.; Shim, J.H., Identification of volatile components in Angelica species using supercritical-CO2 fluid extraction and solid phase microextraction coupled to gas chromatography-mass spectrometry, Biomedical Chromatography, 2006, 20, 11, 1267-1273, https://doi.org/10.1002/bmc.696 . [all data]

Katritzky, Chen, et al., 2000
Katritzky, A.R.; Chen, K.; Maran, U.; Carlson, D.A., QSPR Correlation and predictions of GC retention indexes for methyl-branched hydrocarbons produced by insects, Anal. Chem., 2000, 72, 1, 101-109, https://doi.org/10.1021/ac990800w . [all data]

Orav, Kailas, et al., 1999
Orav, A.; Kailas, T.; Muurisepp, M.; Kann, J., Composition of the oil from waste tires. 1. Fraction boiling at yp to 160 0C, Proc. Estonian Acad. Sci. Chem., 1999, 48, 1, 30-39. [all data]

Durand, Boscher, et al., 1987
Durand, J.P.; Boscher, Y.; Petroff, N.; Berthelin, M., Automatic Gas Chromatographic Determination of Gasoline Components. Application to Octane Number Determination, J. Chromatogr., 1987, 395, 229-240, https://doi.org/10.1016/S0021-9673(01)94113-5 . [all data]


Notes

Go To: Top, Normal alkane RI, non-polar column, temperature ramp, References