Diethyl Phthalate

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Van Den Dool and Kratz RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase BPX-5DB-1DB-55 % Phenyl methyl siloxaneDB-1
Column length (m) 25.30.30.25.30.
Carrier gas He He  
Substrate      
Column diameter (mm) 0.220.20.250.310.25
Phase thickness (μm) 0.250.25 0.31 
Tstart (C) 50.50.50.50.50.
Tend (C) 300.300.250.250.300.
Heat rate (K/min) 5.5.4.5.2.
Initial hold (min) 5.2. 1. 
Final hold (min)  5. 10. 
I 1605.1543.1585.1592.1547.5
ReferenceDickschat, Wenzel, et al., 2004Johnson, Urso, et al., 1997Gómez, Ledbetter, et al., 1993Guisto, Smith, et al., 1993Chang, Sheng, et al., 1989
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryPackedPackedCapillaryCapillary
Active phase DB-1SE-30SE-30SP-2100SP-2100
Column length (m) 30.2.2.  
Carrier gas    H2H2
Substrate  Chromosorb QChromosorb Q  
Column diameter (mm) 0.25    
Phase thickness (μm)      
Tstart (C) 50.100.100.170.170.
Tend (C) 300.    
Heat rate (K/min) 2.10.10.2.4.
Initial hold (min)      
Final hold (min)      
I 1550.91558.1584.1562.221563.47
ReferenceChang, Sheng, et al., 1989Helaimia and Messadi, 1989Helaimia and Messadi, 1989Podmaniczky, Szepesy, et al., 1986Podmaniczky, Szepesy, et al., 1986
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase SP-2100SP-2100SP-2100SP-2100CP Sil 5 CB
Column length (m)      
Carrier gas H2H2H2H2H2
Substrate      
Column diameter (mm)      
Phase thickness (μm)      
Tstart (C) 170.170.170.170.170.
Tend (C)      
Heat rate (K/min) 6.2.4.6.4.
Initial hold (min)      
Final hold (min)      
I 1561.871570.771572.651569.251563.84
ReferencePodmaniczky, Szepesy, et al., 1986Podmaniczky, Szepesy, et al., 1986Podmaniczky, Szepesy, et al., 1986Podmaniczky, Szepesy, et al., 1986Podmaniczky, Szepesy, et al., 1986
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryPacked
Active phase CP Sil 5 CBCP Sil 5 CBSE-30
Column length (m) 26.26. 
Carrier gas   N2
Substrate   Chromosorb Q
Column diameter (mm) 0.320.32 
Phase thickness (μm) 1.251.25 
Tstart (C) 100.100.100.
Tend (C) 250.250.340.
Heat rate (K/min) 10.10.10.
Initial hold (min)    
Final hold (min)    
I 1567.1568.1558.
ReferenceHalket and Schulten, 1985Halket and Schulten, 1985Messadi and Vergnaud, 1979
Comment MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Van Den Dool and Kratz RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Dickschat, Wenzel, et al., 2004
Dickschat, J.S.; Wenzel, S.C.; Bode, H.B.; Muller, R.; Schulz, S., Biosynthesis of Volatiles by the Myxobacterium Myxococcus xanthus, ChemBioChem, 2004, 5, 6, 778-787, https://doi.org/10.1002/cbic.200300813 . [all data]

Johnson, Urso, et al., 1997
Johnson, C.I.; Urso, A.; Geleta, L., Broad spectrum analysis of municipal and industrial effluents discharged into the Peace, Athabasca and Slave river basins: characterization of effluent samples, 1994 - Volume 1 of 2, Northern River Basins Study Project Report No. 121, Norther River Basins Study, Edmonton, Alberta, 1997, 27. [all data]

Gómez, Ledbetter, et al., 1993
Gómez, E.; Ledbetter, C.A.; Hartsell, P.L., Volatile compounds in apricot, plum, and their interspecific hybrids, J. Agric. Food Chem., 1993, 41, 10, 1669-1676, https://doi.org/10.1021/jf00034a029 . [all data]

Guisto, Smith, et al., 1993
Guisto, R.; Smith, S.R.; Stuart, J.D., Gas chromatographic retention indices, mass, and infrared spectra of industrially important adipate esters, J. Chromatogr. Sci., 1993, 31, 6, 225-230, https://doi.org/10.1093/chromsci/31.6.225 . [all data]

Chang, Sheng, et al., 1989
Chang, L.P.; Sheng, L.S.; Yang, M.Z.; An, D.K., Retention index of essential oil in temperature-programmed capillary column gas chromatography, Acta Pharm. Sin., 1989, 24, 11, 847-852. [all data]

Helaimia and Messadi, 1989
Helaimia, F.; Messadi, D., Determination of linear programmed temperature gas chromatography retention indices for some plasticizers, C.R. Acad. Sci. Ser. 2:, 1989, 309, 37-42. [all data]

Podmaniczky, Szepesy, et al., 1986
Podmaniczky, L.; Szepesy, L.; Lakszner, K.; Schomburg, G., Determination of Retention Indices in LPTGC, Chromatographia, 1986, 21, 7, 387-391, https://doi.org/10.1007/BF02346137 . [all data]

Halket and Schulten, 1985
Halket, J.M.; Schulten, H.-R., Thick-film capillary column gas chromatography-field ionization mass spectrometry: A complementary technique for the rapid analysis of volatiles, J. Chromatogr., 1985, 322, 200-205, https://doi.org/10.1016/S0021-9673(01)97672-1 . [all data]

Messadi and Vergnaud, 1979
Messadi, D.; Vergnaud, J.-M., Quick identification and analysis of plasticizers in PVC by programmed-temperature gas chromatography using the best stationary phases, J. Appl. Polym. Sci., 1979, 24, 5, 1215-1225, https://doi.org/10.1002/app.1979.070240507 . [all data]


Notes

Go To: Top, Van Den Dool and Kratz RI, non-polar column, temperature ramp, References