Cyclododecanone

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Gas Chromatography

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Kovats' RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillaryOV-1150.1492.8Rudenko and Rudenko, 2005He; Column diameter: 0.25 mm
CapillaryOV-1170.1505.6Rudenko and Rudenko, 2005He; Column diameter: 0.25 mm
CapillaryOV-1190.1528.9Rudenko and Rudenko, 2005He; Column diameter: 0.25 mm
CapillaryOV-1150.1492.8Rudenko and Rudenko, 2000He; Column diameter: 0.25 mm
CapillaryOV-1170.1505.6Rudenko and Rudenko, 2000He; Column diameter: 0.25 mm
CapillaryOV-1190.1528.9Rudenko and Rudenko, 2000He; Column diameter: 0.25 mm
PackedOV-101220.1570.4Didaoui, Touabet, et al., 1997N2, Chromosorb G HP; Column length: 2. m
CapillarySE-30220.1562.8Didaoui, Touabet, et al., 199727. m/0.4 mm/1.13 μm, N2, Chromosorb G HP
CapillarySE-30200.1574.1Didaoui, Touabet, et al., 199727. m/0.4 mm/0.1 μm, N2, Chromosorb G HP

Kovats' RI, non-polar column, custom temperature program

View large format table.

Column type Active phase I Reference Comment
PackedSE-301524.Ramsey, Lee, et al., 1980He, Chromosorb G HP (80-100 mesh); Column length: 1.5 m; Program: not specified

Kovats' RI, polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillaryCarbowax 40M150.1923.2Rudenko and Rudenko, 2005He; Column diameter: 0.25 mm
CapillaryCarbowax 40M170.1956.4Rudenko and Rudenko, 2005He; Column diameter: 0.25 mm
CapillaryCarbowax 40M190.1992.7Rudenko and Rudenko, 2005He; Column diameter: 0.25 mm
CapillaryCarbowax 40M150.1923.2Rudenko and Rudenko, 2000He; Column diameter: 0.25 mm
CapillaryCarbowax 40M170.1956.4Rudenko and Rudenko, 2000He; Column diameter: 0.25 mm
CapillaryCarbowax 40M190.1992.7Rudenko and Rudenko, 2000He; Column diameter: 0.25 mm

Normal alkane RI, non-polar column, custom temperature program

View large format table.

Column type Active phase I Reference Comment
OtherMethyl Silicone1524.Ardrey and Moffat, 1981Program: not specified

References

Go To: Top, Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Rudenko and Rudenko, 2005
Rudenko, B.A.; Rudenko, G.I., Gas chromatography with open tubular columns of cyclododecane derivatives, J. Anal. Chem. USSR (Engl. Transl.), 2005, 60, 4, 345-348. [all data]

Rudenko and Rudenko, 2000
Rudenko, B.A.; Rudenko, G.I., Capillary chromatography of cyclododecane derivatives, Proceedings, 23rd ISCC; CD-ROM, 2000, retrieved from http://www.richrom.com/assets/CD23PDF. [all data]

Didaoui, Touabet, et al., 1997
Didaoui, L.; Touabet, A.; Meklati, B.Y., Comparison of mathematical methods for the calculation of retention indices at high temperature in gas chromatography, J. Hi. Res. Chromatogr., 1997, 20, 11, 605-610, https://doi.org/10.1002/jhrc.1240201107 . [all data]

Ramsey, Lee, et al., 1980
Ramsey, J.D.; Lee, T.D.; Osselton, M.D.; Moffat, A.C., Gas-liquid chromatographic retention indices of 296 non-drug substances on SE-30 or OV-1 likely to be encountered in toxicological analyses, J. Chromatogr., 1980, 184, 2, 185-206, https://doi.org/10.1016/S0021-9673(00)85641-1 . [all data]

Ardrey and Moffat, 1981
Ardrey, R.E.; Moffat, A.C., Gas-liquid chromatographic retention indices of 1318 substances of toxicological interest on SE-30 or OV-1 stationary phase, J. Chromatogr., 1981, 220, 3, 195-252, https://doi.org/10.1016/S0021-9673(00)81925-1 . [all data]


Notes

Go To: Top, Gas Chromatography, References