2-Butanone

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase DB-WaxDB-WaxDB-WaxDB-WaxDB-Wax
Column length (m) 30.30.30.30.30.
Carrier gas      
Substrate      
Column diameter (mm) 0.320.320.320.320.32
Phase thickness (μm)      
Temperature (C) 40.50.60.70.80.
I 917.39922.33925.59928.27931.34
ReferenceCiaznska-Halarewicz and Kowalska, 2003Ciaznska-Halarewicz and Kowalska, 2003Ciaznska-Halarewicz and Kowalska, 2003Ciaznska-Halarewicz and Kowalska, 2003Ciaznska-Halarewicz and Kowalska, 2003
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase DB-WaxDB-WaxDB-WaxDB-WaxDB-Wax
Column length (m) 30.30.30.30.30.
Carrier gas      
Substrate      
Column diameter (mm) 0.320.320.320.320.32
Phase thickness (μm)      
Temperature (C) 90.100.110.120.130.
I 935.77940.31943.44946.71949.95
ReferenceCiaznska-Halarewicz and Kowalska, 2003Ciaznska-Halarewicz and Kowalska, 2003Ciaznska-Halarewicz and Kowalska, 2003Ciaznska-Halarewicz and Kowalska, 2003Ciaznska-Halarewicz and Kowalska, 2003
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase DB-WaxDB-WaxDB-WaxHP-InnowaxHP-Innowax
Column length (m) 30.30.30.30.30.
Carrier gas HeHeHe  
Substrate      
Column diameter (mm) 0.320.320.320.320.32
Phase thickness (μm) 1.1.1.0.50.5
Temperature (C) 75.100.125.110.50.
I 937.60938.60947.76932.3919.8
ReferenceCiazynska-Halarewicz, Borucka, et al., 2002Ciazynska-Halarewicz, Borucka, et al., 2002Ciazynska-Halarewicz, Borucka, et al., 2002Héberger and Görgényi, 1999Héberger and Görgényi, 1999
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryPacked
Active phase HP-InnowaxHP-InnowaxSupelcowax-10Carbowax 20M
Column length (m) 30.30.60.2.
Carrier gas   N2N2
Substrate    Kieselgur (60-100 mesh)
Column diameter (mm) 0.320.320.75 
Phase thickness (μm) 0.50.5  
Temperature (C) 70.90.60.75.
I 923.7927.8919.930.
ReferenceHéberger and Görgényi, 1999Héberger and Görgényi, 1999Castello, Vezzani, et al., 1991Goebel, 1982
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Kovats' RI, polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Ciaznska-Halarewicz and Kowalska, 2003
Ciaznska-Halarewicz, K.; Kowalska, T., A study of the dependence of the Kováts retention index on the temperature of analysis on stationary phases of different polarity, Acta Chromatogr., 2003, 13, 69-80. [all data]

Ciazynska-Halarewicz, Borucka, et al., 2002
Ciazynska-Halarewicz, K.; Borucka, H.E.; Kowalska, T., Temperature dependence of Kováts indices in gas chromatography. Statistical and thermodynamic verification of a 'kinetic' model, Acta Chromatogr., 2002, 12, 65-79. [all data]

Héberger and Görgényi, 1999
Héberger, K.; Görgényi, M., Principal component analysis of Kováts indices for carbonyl compounds in capillary gas chromatography, J. Chromatogr., 1999, 845, 1-2, 21-31, https://doi.org/10.1016/S0021-9673(99)00323-4 . [all data]

Castello, Vezzani, et al., 1991
Castello, G.; Vezzani, S.; Gerbino, T., Gas chromatographic separation and automatic identification of complex mixtures of organic solvents in indrustrial wates, J. Chromatogr., 1991, 585, 2, 273-280, https://doi.org/10.1016/0021-9673(91)85088-W . [all data]

Goebel, 1982
Goebel, K.-J., Gaschromatographische Identifizierung Niedrig Siedender Substanzen Mittels Retentionsindices und Rechnerhilfe, J. Chromatogr., 1982, 235, 1, 119-127, https://doi.org/10.1016/S0021-9673(00)95793-5 . [all data]


Notes

Go To: Top, Kovats' RI, polar column, isothermal, References