1-Propanol, 2-methyl-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Normal alkane RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type PackedCapillaryPackedPackedPacked
Active phase SE-30DB-1SE-30SynachromSynachrom
Column length (m) 1.60. 1.51.5
Carrier gas  He HeliumHelium
Substrate    Synachrom (60-80 mesh)Synachrom (60-80 mesh)
Column diameter (mm)  0.32   
Phase thickness (μm)  1.   
Temperature (C) 100.60.70.150.150.
I 612.612.655.586.588.
ReferenceZhou and Wu, 2007Shimadzu, 2003Yabumoto, Jennings, et al., 1977Dufka, Malinsky, et al., 1971Dufka, Malinsky, et al., 1971
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type Packed
Active phase DC-400
Column length (m) 3.0
Carrier gas Helium
Substrate Gas-Pak (60-80 mesh)
Column diameter (mm)  
Phase thickness (μm)  
Temperature (C) 150.
I 580.
ReferenceAnderson, 1968
Comment MSDC-RI

References

Go To: Top, Normal alkane RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Zhou and Wu, 2007
Zhou, L.; Wu, Q., Model of artificial neural network for quantitative structure-retention relations of saturated alcohols, J. Southwest Univ. (Nat. Sci. Edn.), 2007, 33, 6, 1369-1372. [all data]

Shimadzu, 2003
Shimadzu, Gas chromatography analysis of organic solvents using capillary columns (No. 3), 2003, retrieved from http://www.shimadzu.com/apps/form.cfm. [all data]

Yabumoto, Jennings, et al., 1977
Yabumoto, K.; Jennings, W.G.; Yamaguchi, M., Gas chromatographic retention as identification criteria, Anal. Biochem., 1977, 78, 1, 244-251, https://doi.org/10.1016/0003-2697(77)90029-X . [all data]

Dufka, Malinsky, et al., 1971
Dufka, O.; Malinsky, J.; Vladyka, J., Sorpcni materialy pro plynovou chromatographii - III, Chemicky promysl., 1971, 21/46, 9, 459-463. [all data]

Anderson, 1968
Anderson, D.G., USe of Kovats retention indices and response factors for the qualitative and quantitative analysis of coating solvents, J. Paint Technol., 1968, 40, 527, 549-557. [all data]