Triethyl phosphate

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Van Den Dool and Kratz RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase OV-1SE-54DB-1DB-5DB-5
Column length (m) 15.25.15.15.15.
Carrier gas HeHeHeHeHe
Substrate      
Column diameter (mm) 0.320.320.530.530.53
Phase thickness (μm) 0.250.25   
Tstart (C) 50.40.50.50.50.
Tend (C) 280.280.   
Heat rate (K/min) 10.10.10.10.10.
Initial hold (min) 2.1.2.2.2.
Final hold (min) 10.10.   
I 1090.1137.21088.1120.51121.3
ReferenceKostiainen, 2000Kostiainen, 2000Hancock and Peters, 1991Hancock and Peters, 1991Hancock and Peters, 1991
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryPacked
Active phase DB-5DB-1DB-5SE-30
Column length (m) 15.15.15. 
Carrier gas HeHeHeN2
Substrate    Chromosorb Q
Column diameter (mm) 0.530.320.32 
Phase thickness (μm)  0.250.25 
Tstart (C) 50.50.50.100.
Tend (C)  300.300.340.
Heat rate (K/min) 10.10.10.10.
Initial hold (min) 2.2.2. 
Final hold (min)  5.  
I 1121.51090.71137.21091.
ReferenceHancock and Peters, 1991D'Agostino and Provost, 1985D'Agostino and Provost, 1985Messadi and Vergnaud, 1979
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Van Den Dool and Kratz RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Kostiainen, 2000
Kostiainen, O., Gas Chromatography in Screening of Chemicals Related to the Chemical Weapons Convention in Encyclopedia of Analytical Chemistry, Meyers, R.A., ed(s)., John Wiley Sons Ltd, Chichester, 2000, 963-979. [all data]

Hancock and Peters, 1991
Hancock, J.R.; Peters, G.R., Retention index monitoring of compounds of chemical defence interest using thermal desorption gas chromatography, J. Chromatogr., 1991, 538, 2, 249-257, https://doi.org/10.1016/S0021-9673(01)88845-2 . [all data]

D'Agostino and Provost, 1985
D'Agostino, P.A.; Provost, L.R., Gas chromatographic retention indices of chemical warfare agents and simulants, J. Chromatogr., 1985, 331, 47-54, https://doi.org/10.1016/0021-9673(85)80005-4 . [all data]

Messadi and Vergnaud, 1979
Messadi, D.; Vergnaud, J.-M., Quick identification and analysis of plasticizers in PVC by programmed-temperature gas chromatography using the best stationary phases, J. Appl. Polym. Sci., 1979, 24, 5, 1215-1225, https://doi.org/10.1002/app.1979.070240507 . [all data]


Notes

Go To: Top, Van Den Dool and Kratz RI, non-polar column, temperature ramp, References