fluorosulphuric acid


Gas Phase Heat Capacity (Shomate Equation)

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Cp° = A + B*t + C*t2 + D*t3 + E/t2
H° − H°298.15= A*t + B*t2/2 + C*t3/3 + D*t4/4 − E/t + F − H
S° = A*ln(t) + B*t + C*t2/2 + D*t3/3 − E/(2*t2) + G
    Cp = heat capacity (J/mol*K)
    H° = standard enthalpy (kJ/mol)
    S° = standard entropy (J/mol*K)
    t = temperature (K) / 1000.

View plot Requires a JavaScript / HTML 5 canvas capable browser.

Temperature (K) 298. to 1100.1100. to 6000.
A 39.47412121.6824
B 182.33505.915214
C -152.9219-1.141158
D 47.857010.076383
E -0.559748-10.68782
F -773.6174-816.3737
G 293.8913405.2991
H -753.1200-753.1200
ReferenceChase, 1998Chase, 1998
Comment Data last reviewed in June, 1972 Data last reviewed in June, 1972
Temperature
(K)
Cp
(J/mol*K)

(J/mol*K)
-(G° - H°298.15)/T
(J/mol*K)
H° - H°298.15
(kJ/mol)
298.75.19297.2297.3-0.01
300.75.48297.7297.30.14
400.87.51321.2300.48.32
500.96.15341.7306.617.53
600.102.6359.8314.027.48
700.107.4376.0321.737.99
800.111.1390.6329.548.93
900.113.9403.9337.060.19
1000.116.2416.0344.371.69
1100.118.2427.2351.383.42
Temperature
(K)
Cp
(J/mol*K)

(J/mol*K)
-(G° - H°298.15)/T
(J/mol*K)
H° - H°298.15
(kJ/mol)
1100.118.1427.2351.383.41
1200.119.8437.5358.195.31
1300.121.3447.2364.6107.4
1400.122.5456.2370.8119.6
1500.123.5464.7376.8131.9
1600.124.4472.7382.5144.3
1700.125.1480.2388.1156.7
1800.125.8487.4393.4169.3
1900.126.4494.2398.5181.9
2000.126.9500.7403.5194.5
2100.127.4506.9408.2207.3
2200.127.8512.9412.9220.0
2300.128.2518.6417.3232.8
2400.128.5524.0421.7245.6
2500.128.8529.3425.9258.5
2600.129.1534.3429.9271.4
2700.129.4539.2433.9284.3
2800.129.6543.9437.7297.3
2900.129.8548.5441.5310.3
3000.130.0552.9445.1323.3
3100.130.2557.1448.7336.3
3200.130.4561.3452.1349.3
3300.130.5565.3455.5362.3
3400.130.7569.2458.8375.4
3500.130.8573.0462.0388.5
3600.130.9576.7465.1401.6
3700.131.0580.3468.2414.7
3800.131.1583.8471.2427.8
3900.131.2587.2474.1440.9
4000.131.3590.5477.0454.0
4100.131.4593.7479.8467.1
4200.131.4596.9482.5480.3
4300.131.5600.0485.2493.4
4400.131.6603.0487.9506.6
4500.131.6606.0490.5519.8
4600.131.7608.9493.0532.9
4700.131.7611.7495.5546.1
4800.131.8614.5498.0559.3
4900.131.8617.2500.4572.4
5000.131.8619.8502.7585.6
5100.131.9622.5505.0598.8
5200.131.9625.0507.3612.0
5300.132.0627.5509.6625.2
5400.132.0630.0511.8638.4
5500.132.1632.4514.0651.6
5600.132.1634.8516.1664.8
5700.132.1637.1518.2678.0
5800.132.2639.4520.3691.2
5900.132.2641.7522.3704.5
6000.132.3643.9524.3717.7

References

Go To: Top, Gas Phase Heat Capacity (Shomate Equation), Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Chase, 1998
Chase, M.W., Jr., NIST-JANAF Themochemical Tables, Fourth Edition, J. Phys. Chem. Ref. Data, Monograph 9, 1998, 1-1951. [all data]


Notes

Go To: Top, Gas Phase Heat Capacity (Shomate Equation), References


Copyright for NIST Standard Reference Data is governed by the Standard Reference Data Act.