lead difluoride

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Gas Phase Heat Capacity (Shomate Equation)

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Cp° = A + B*t + C*t2 + D*t3 + E/t2
H° − H°298.15= A*t + B*t2/2 + C*t3/3 + D*t4/4 − E/t + F − H
S° = A*ln(t) + B*t + C*t2/2 + D*t3/3 − E/(2*t2) + G
    Cp = heat capacity (J/mol*K)
    H° = standard enthalpy (kJ/mol)
    S° = standard entropy (J/mol*K)
    t = temperature (K) / 1000.

View plot Requires a JavaScript / HTML 5 canvas capable browser.

Temperature (K) 1500. - 6000.
A 57.28482
B 0.779768
C -0.210946
D 0.017981
E -0.595576
F -454.2443
G 358.4098
H -435.1360
ReferenceChase, 1998
Comment Data last reviewed in December, 1973
Temperature
(K)
Cp
(J/mol*K)

(J/mol*K)
-(G° - H°298.15)/T
(J/mol*K)
H° - H°298.15
(kJ/mol)
1500.57.78382.7337.567.88
1600.57.83386.5340.473.66
1700.57.88390.0343.279.45
1800.57.93393.3345.985.24
1900.57.96396.4348.591.03
2000.58.00399.4351.096.83
2100.58.02402.2353.3102.6
2200.58.05404.9355.6108.4
2300.58.07407.5357.8114.2
2400.58.09410.0359.9120.0
2500.58.10412.3362.0125.9
2600.58.11414.6364.0131.7
2700.58.12416.8365.9137.5
2800.58.13418.9367.7143.3
2900.58.14421.0369.5149.1
3000.58.14422.9371.3154.9
3100.58.15424.8373.0160.7
3200.58.15426.7374.6166.5
3300.58.15428.5376.2172.4
3400.58.15430.2377.8178.2
3500.58.15431.9379.3184.0
3600.58.15433.5380.8189.8
3700.58.15435.1382.3195.6
3800.58.15436.7383.7201.4
3900.58.14438.2385.0207.3
4000.58.14439.7386.4213.1
4100.58.14441.1387.7218.9
4200.58.14442.5389.0224.7
4300.58.13443.9390.3230.5
4400.58.13445.2391.5236.3
4500.58.13446.5392.7242.1
4600.58.13447.8393.9247.9
4700.58.13449.0395.0253.8
4800.58.13450.3396.2259.6
4900.58.13451.5397.3265.4
5000.58.13452.6398.4271.2
5100.58.14453.8399.5277.0
5200.58.14454.9400.5282.8
5300.58.15456.0401.6288.6
5400.58.16457.1402.6294.5
5500.58.16458.2403.6300.3
5600.58.17459.2404.6306.1
5700.58.19460.2405.5311.9
5800.58.20461.3406.5317.7
5900.58.22462.3407.4323.6
6000.58.24463.2408.3329.4

References

Go To: Top, Gas Phase Heat Capacity (Shomate Equation), Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Chase, 1998
Chase, M.W., Jr., NIST-JANAF Themochemical Tables, Fourth Edition, J. Phys. Chem. Ref. Data, Monograph 9, 1998, 1-1951. [all data]


Notes

Go To: Top, Gas Phase Heat Capacity (Shomate Equation), References