Camphor

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryPackedPacked
Active phase SE-30SE-30PB-1OV-101OV-101
Column length (m)  40.42.2.2.
Carrier gas    ArAr
Substrate    W-AW-DMCSW-AW-DMCS
Column diameter (mm)  0.350.32  
Phase thickness (μm)  0.35   
Temperature (C) 120.100.130.140.150.
I 1135.1135.11146.1153.1159.
ReferenceTudor and Moldovan, 1999Tudor, 1997Engewald, Knobloch, et al., 1991Szabolcs, Benecke, et al., 1985Szabolcs, Benecke, et al., 1985
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPackedCapillaryCapillaryCapillary
Active phase OV-101OV-101OV-101OV-101OV-101
Column length (m) 2.2.   
Carrier gas ArAr   
Substrate W-AW-DMCSW-AW-DMCS   
Column diameter (mm)      
Phase thickness (μm)      
Temperature (C) 160.170.140.150.160.
I 1166.1173.1153.1159.1166.
ReferenceSzabolcs, Benecke, et al., 1985Szabolcs, Benecke, et al., 1985Benecke, Thieme, et al., 1982Benecke, Thieme, et al., 1982Benecke, Thieme, et al., 1982
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type Capillary
Active phase OV-101
Column length (m)  
Carrier gas  
Substrate  
Column diameter (mm)  
Phase thickness (μm)  
Temperature (C) 170.
I 1173.
ReferenceBenecke, Thieme, et al., 1982
Comment MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Tudor and Moldovan, 1999
Tudor, E.; Moldovan, D., Temperature Dependence of the Retention Index for Perfumery Compounds on a Se-30 Glass Capillary Column. II. The Hyperbolic Equation, J. Chromatogr., 1999, 848, 1-2, 215-227, https://doi.org/10.1016/S0021-9673(99)00412-4 . [all data]

Tudor, 1997
Tudor, E., Temperature dependence of the retention index for perfumery compounds on a SE-30 glass capillary column. I. Linear equations, J. Chromatogr. A, 1997, 779, 1-2, 287-297, https://doi.org/10.1016/S0021-9673(97)00453-6 . [all data]

Engewald, Knobloch, et al., 1991
Engewald, W.; Knobloch, T.; Haufe, G.; Muller, M.; Pohris, V., A Novel Method for Terpene Pattern Determination of Essential Oils by Selectivity Tuning in GC, Fresenius' J. Anal. Chem., 1991, 341, 10, 641-643, https://doi.org/10.1007/BF00322279 . [all data]

Szabolcs, Benecke, et al., 1985
Szabolcs, N.; Benecke, R.; Thieme, H., Természetes eredetu növényi anyagok gázkromatográfiás retenciós tulajdonságai. I. A lavandula- és lavandinolaj fo kimponenseinek retenciós indexei, Acta Pharm. Hung., 1985, 55, 49-58. [all data]

Benecke, Thieme, et al., 1982
Benecke, R.; Thieme, H.; Nyiredy, Sz., Retentionsverhalten der Hauptkomponenten der Lavendel und Lavandinöle an Verschiedenen stationären Phasen in Abhängigkeit von der Säulentemperatur, J. Chromatogr., 1982, 238, 1, 75-87, https://doi.org/10.1016/S0021-9673(00)82713-2 . [all data]


Notes

Go To: Top, Kovats' RI, non-polar column, isothermal, References