Dimethyl sulfide
- Formula: C2H6S
- Molecular weight: 62.134
- IUPAC Standard InChIKey: QMMFVYPAHWMCMS-UHFFFAOYSA-N
- CAS Registry Number: 75-18-3
- Chemical structure:
This structure is also available as a 2d Mol file or as a computed 3d SD file
The 3d structure may be viewed using Java or Javascript. - Isotopologues:
- Other names: Methane, thiobis-; Methyl sulfide; Dimethyl monosulfide; Dimethyl thioether; DMS; Methyl monosulfide; 2-Thiapropane; Dimethyl sulphide; Thiobismethane; (CH3)2S; Dimethylsulfid; Exact-S; Methyl sulphide; Methylthiomethane; Sulfure de methyle; 2-Thiopropane; UN 1164; Methyl thioether; Sulfide, methyl-; Methane, 1,1'-thiobis-; (Methylsulfanyl)methane
- Permanent link for this species. Use this link for bookmarking this species for future reference.
- Information on this page:
- Other data available:
- Data at other public NIST sites:
- Options:
Data at NIST subscription sites:
- NIST / TRC Web Thermo Tables, "lite" edition (thermophysical and thermochemical data)
- NIST / TRC Web Thermo Tables, professional edition (thermophysical and thermochemical data)
NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.
Van Den Dool and Kratz RI, polar column, custom temperature program
Go To: Top, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Column type | Capillary | Capillary | Capillary | Capillary | Capillary |
---|---|---|---|---|---|
Active phase | Supelcowax-10 | Supelcowax-10 | CP-Wax 52CB | DB-Wax | FFAP |
Column length (m) | 30. | 30. | 60. | 30. | 60. |
Carrier gas | He | He | He | He | |
Substrate | |||||
Column diameter (mm) | 0.25 | 0.25 | 0.25 | 0.32 | 0.25 |
Phase thickness (μm) | 0.25 | 0.25 | 0.25 | 0.5 | 0.5 |
Program | 35C(8min) => 4C/min => 60C => 6C/min => 160C => 20C/min => 200C(1min) | 40C(2min) => 40C/min => 60C(2min) => 5C/min => 240C | 45C(5min) => 10C/min => 80C => 2C/min => 240C | 40C(5min) => 10C/min => 160C => 15C/min => 230C | 50C(3min) => 3C/min => 100C => 10C/min => 220C (13.5min) |
I | 745. | 715. | 763. | 737. | 751. |
Reference | Bianchi, Careri, et al., 2007 | Majcher and Jelen, 2007 | Romeo, Ziino, et al., 2007 | Hallier, Prost, et al., 2005 | Ranau and Steinhart, 2005 |
Comment | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI |
Column type | Capillary | Capillary | Capillary |
---|---|---|---|
Active phase | DB-Wax | DB-Wax | FFAP |
Column length (m) | 30. | 30. | 50. |
Carrier gas | He | He | He |
Substrate | |||
Column diameter (mm) | 0.32 | 0.32 | 0.25 |
Phase thickness (μm) | 0.5 | 0.5 | 0.25 |
Program | 50C => 6C/min => 70C => 4C/min => 150C => 10C/min => 250C | 50C => 6C/min => 70C => 4C/min => 150C => 10C/min => 250C | 20C (5min) => 2C/min => 70C => 4C/min => 210C |
I | 773. | 773. | 733. |
Reference | Pennarun, Prost, et al., 2003 | Pennarun, Prost, et al., 2002 | Yasuhara, 1987 |
Comment | MSDC-RI | MSDC-RI | MSDC-RI |
References
Go To: Top, Van Den Dool and Kratz RI, polar column, custom temperature program, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Bianchi, Careri, et al., 2007
Bianchi, F.; Careri, M.; Mangia, A.; Musci, M.,
Retention indices in the analysis of food aroma volatile compounds in temperature-programmed gas chromatography: Database creation and evaluation of precision and robustness,
J. Sep. Sci., 2007, 39, 4, 563-572, https://doi.org/10.1002/jssc.200600393
. [all data]
Majcher and Jelen, 2007
Majcher, M.A.; Jelen, H.H.,
Effect of Cysteine and Cystine Addition on Sensory Profile and Potent Odorants of Extruded Potato Snacks,
J. Agric. Food Chem., 2007, 55, 14, 5754-5760, https://doi.org/10.1021/jf0703147
. [all data]
Romeo, Ziino, et al., 2007
Romeo, V.; Ziino, M.; Giuffrrida, D.; Condurso, C.; Verzera, A.,
Flavour profile of capers (Capparis spinosa L.) from the Eolian Archipelago by HS-SPME/GC?MS,
Food Chem., 2007, 101, 3, 1272-1278, https://doi.org/10.1016/j.foodchem.2005.12.029
. [all data]
Hallier, Prost, et al., 2005
Hallier, A.; Prost, C.; Serot, T.,
Influence in rearing conditions on the volatile compounds of cooked fillets of Silurus glanis (European catfish),
J. Agric. Food Chem., 2005, 53, 18, 7204-7211, https://doi.org/10.1021/jf050559o
. [all data]
Ranau and Steinhart, 2005
Ranau, R.; Steinhart, H.,
Identification and evaluation of volatile odor-active pollutants from different odor emission sources in the food industry,
Eur. Food Res. Technol., 2005, 220, 2, 226-231, https://doi.org/10.1007/s00217-004-1073-4
. [all data]
Pennarun, Prost, et al., 2003
Pennarun, A.-L.; Prost, C.; Haure, J.; Demaimay, M.,
Comparison of two microalgal diets. 2. Influence on odorant composition and organoleptic qualities of raw oysters (Crassostrea gigas),
J. Agric. Food Chem., 2003, 51, 7, 2011-2018, https://doi.org/10.1021/jf020549c
. [all data]
Pennarun, Prost, et al., 2002
Pennarun, A.L.; Prost, C.; Demaimay, M.,
Identification and origin of the character-impact compounds of raw oyster Crassostrea gigas,
J. Sci. Food Agric., 2002, 82, 14, 1652-1660, https://doi.org/10.1002/jsfa.1236
. [all data]
Yasuhara, 1987
Yasuhara, A.,
Identification of Volatile Compounds in Poultry Manure by Gas Chromatography-Mass Spectrometry,
J. Chromatogr., 1987, 387, 371-378, https://doi.org/10.1016/S0021-9673(01)94539-X
. [all data]
Notes
Go To: Top, Van Den Dool and Kratz RI, polar column, custom temperature program, References
- Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.
- Customer support for NIST Standard Reference Data products.