Carbon disulfide
- Formula: CS2
- Molecular weight: 76.141
- IUPAC Standard InChIKey: QGJOPFRUJISHPQ-UHFFFAOYSA-N
- CAS Registry Number: 75-15-0
- Chemical structure:
This structure is also available as a 2d Mol file or as a computed 3d SD file
The 3d structure may be viewed using Java or Javascript. - Other names: Carbon bisulfide; Carbon sulfide (CS2); Dithiocarbonic anhydride; CS2; Carbon sulfide; Carbon-disulphide-; Carbon bisulphide; Carbon sulphide; Kohlendisulfid; Koolstofdisulfide; NCI-C04591; Rcra waste number P022; Schwefelkohlenstoff; Solfuro di carbonio; Sulphocarbonic anhydride; UN 1131; Weeviltox; Wegla dwusiarczek; Alcohol of sulfur; Carbon bisulfuret; Methyl disulfide; Sulfocarbonic anhydride
- Permanent link for this species. Use this link for bookmarking this species for future reference.
- Information on this page:
- Other data available:
- Data at other public NIST sites:
- Options:
Data at NIST subscription sites:
- NIST / TRC Web Thermo Tables, "lite" edition (thermophysical and thermochemical data)
- NIST / TRC Web Thermo Tables, professional edition (thermophysical and thermochemical data)
NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.
Normal alkane RI, non-polar column, temperature ramp
Go To: Top, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Column type | Capillary | Capillary | Capillary | Capillary | Capillary |
---|---|---|---|---|---|
Active phase | Polydimethyl siloxane: CP-Sil 5 CB | HP-5 MS | OV-101 | PONA | PONA |
Column length (m) | 60. | 30. | 25. | 50. | 50. |
Carrier gas | Helium | Helium | N2/He | Helium | |
Substrate | |||||
Column diameter (mm) | 0.25 | 0.25 | 0.20 | 0.20 | 0.20 |
Phase thickness (μm) | 1.0 | 0.25 | 0.10 | 0.50 | 0.50 |
Tstart (C) | 45. | 35. | 50. | 30. | 30. |
Tend (C) | 210. | 300. | 250. | 150. | 170. |
Heat rate (K/min) | 3.6 | 3. | 6. | 2. | 2. |
Initial hold (min) | 1.45 | 5. | |||
Final hold (min) | 2.72 | 15. | |||
I | 517. | 536. | 530. | 537. | 537. |
Reference | Bramston-Cook, 2013 | Kotowska, Zalikowski, et al., 2012 | Zenkevich, 2005 | Yang, Wang, et al., 2003 | Yang, Yang, et al., 2003 |
Comment | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI |
Column type | Capillary | Capillary | Capillary | Capillary |
---|---|---|---|---|
Active phase | SPB-5 | HP-5 | DB-1 | OV-101 |
Column length (m) | 60. | 60. | 50. | 50. |
Carrier gas | He | He | ||
Substrate | ||||
Column diameter (mm) | 0.32 | 0.32 | 0.32 | 0.31 |
Phase thickness (μm) | 1. | 1. | ||
Tstart (C) | 40. | 40. | 0. | 0. |
Tend (C) | 200. | 240. | 250. | 225. |
Heat rate (K/min) | 3. | 3. | 3. | 3. |
Initial hold (min) | 5. | 1. | ||
Final hold (min) | 5. | |||
I | 533. | 536. | 517. | 512. |
Reference | Pérès, Begnaud, et al., 2002 | García, Martín, et al., 2000 | Habu, Flath, et al., 1985 | del Rosario, de Lumen, et al., 1984 |
Comment | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI |
References
Go To: Top, Normal alkane RI, non-polar column, temperature ramp, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Bramston-Cook, 2013
Bramston-Cook, R.,
Kovats indices for C2-C13 hydrocarbons and selected oxygenated/halocarbons with 100 % dimethylpolysiloxane columns, 2013, retrieved from http://lotusinstruments.com/monographs/List .... [all data]
Kotowska, Zalikowski, et al., 2012
Kotowska, U.; Zalikowski, M.; Isidorov, V.A.,
HS-SPME/GC-MS analysis of volatile and semi-volatile organic compounds emitted from municipal sewage sludge,
Environ. Monit. Asses., 2012, 184, 5, 2893-2907, https://doi.org/10.1007/s10661-011-2158-8
. [all data]
Zenkevich, 2005
Zenkevich, I.G.,
Experimentally measured retention indices., 2005. [all data]
Yang, Wang, et al., 2003
Yang, Y.-T.; Wang, Z.; Han. J.-H.; Tian, H.-P.; Yang, H.-Y.,
Determination of sulfur compounds in gasoline fraction of microreactor products by gas chromatography - Atomic emission detector,
Petrochemical Technology (Shiyou Huagong), 2003, 32, 11, 995-998. [all data]
Yang, Yang, et al., 2003
Yang, Y.T.; Yang, H.Y.; Zong, B.N.; Lu, W.Z.,
determination and distribution of sulfur compounds in gasoline by gas chromatography-atomic emission detector,
Chinise J. Anal. Chem. (Fenxi Huaxue), 2003, 31, 10, 1153-1158. [all data]
Pérès, Begnaud, et al., 2002
Pérès, C.; Begnaud, F.; Berdagué, J.-L.,
Fast characterization of Camembert cheeses by static headspace-mass spectrometry,
Sens. Actuators, 2002, 87, 3, 491-497, https://doi.org/10.1016/S0925-4005(02)00298-8
. [all data]
García, Martín, et al., 2000
García, C.; Martín, A.; Timón, M.L.; Córdoba, J.J.,
Microbial populations and volatile compounds in the 'bone taint' spoilage of dry cured ham,
Lett. Appl. Microbiol., 2000, 30, 1, 61-66, https://doi.org/10.1046/j.1472-765x.2000.00663.x
. [all data]
Habu, Flath, et al., 1985
Habu, T.; Flath, R.A.; Mon, T.R.; Morton, J.F.,
Volatile components of Rooibos tea (Aspalathus linearis),
J. Agric. Food Chem., 1985, 33, 2, 249-254, https://doi.org/10.1021/jf00062a024
. [all data]
del Rosario, de Lumen, et al., 1984
del Rosario, R.; de Lumen, B.O.; Habu, T.; Flath, R.A.; Mon, T.R.; Teranishi, R.,
Comparison of headspace volatiles from winged beans and soybeans,
J. Agric. Food Chem., 1984, 32, 5, 1011-1015, https://doi.org/10.1021/jf00125a015
. [all data]
Notes
Go To: Top, Normal alkane RI, non-polar column, temperature ramp, References
- Symbols used in this document:
Tend Final temperature Tstart Initial temperature - Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.
- Customer support for NIST Standard Reference Data products.