Home Symbol which looks like a small house Up Solid circle with an upward pointer in it

NOTICE: Due to scheduled maintenance at our Gaithersburg campus, this site will not be available from 5:00 pm EDT (21:00 UTC) on Friday October 25 until 5:00 pm (21:00 UTC) on Sunday October 27. We apologize for any inconvenience this outage may cause.

Ethanethiol

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Normal alkane RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase OV-101PONAPONAOV-101OV-101
Column length (m) 25.50.50.50.50.
Carrier gas N2/HeN2 N2N2
Substrate      
Column diameter (mm) 0.200.200.200.250.25
Phase thickness (mum) 0.100.500.50  
Tstart (C) 50.35.30.80.80.
Tend (C) 250.170.150.200.200.
Heat rate (K/min) 6.2.2.2.2.
Initial hold (min)      
Final hold (min)      
I 502.482.496.500.501.
ReferenceZenkevich, 2005Yang, Wang, et al., 2004Yang, Wang, et al., 2003Tamura, Nakamoto, et al., 1995Tamura, Nakamoto, et al., 1995
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillary
Active phase OV-101OV-101
Column length (m) 50.50.
Carrier gas NitrogenNitrogen
Substrate   
Column diameter (mm) 0.250.25
Phase thickness (mum)   
Tstart (C) 70.80.
Tend (C) 200.200.
Heat rate (K/min) 2.2.
Initial hold (min)   
Final hold (min)   
I 500.500.
ReferenceSugisawa, Nakamura, et al., 1990Sugisawa, Nakamura, et al., 1990
Comment MSDC-RI MSDC-RI

References

Go To: Top, Normal alkane RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Zenkevich, 2005
Zenkevich, I.G., Experimentally measured retention indices., 2005. [all data]

Yang, Wang, et al., 2004
Yang, Y.; Wang, Z.; Zong, B.; Yang, H., Determination of sulfur compounds in fluid catalytic cracking gasoline by gas chromatography with a sulfur chemiluminiscence detector, Chin. J. Chromatogr., 2004, 22, 3, 216-219. [all data]

Yang, Wang, et al., 2003
Yang, Y.-T.; Wang, Z.; Han. J.-H.; Tian, H.-P.; Yang, H.-Y., Determination of sulfur compounds in gasoline fraction of microreactor products by gas chromatography - Atomic emission detector, Petrochemical Technology (Shiyou Huagong), 2003, 32, 11, 995-998. [all data]

Tamura, Nakamoto, et al., 1995
Tamura, H.; Nakamoto, H.; Yang, R.-H.; Sugisawa, H., Characteristic aroma compounds in green algae (Ulva pertusa) volatiles, Nippon Shokuhin Kagaku Kogaku Kaishi, 1995, 42, 11, 887-891, https://doi.org/10.3136/nskkk.42.887 . [all data]

Sugisawa, Nakamura, et al., 1990
Sugisawa, H.; Nakamura, K.; Tamura, H., The aroma profile of the volatile in marine green algae (Ulva pertusa), Food Reviews International, 1990, 6, 4, 573-589, https://doi.org/10.1080/87559129009540893 . [all data]


Notes

Go To: Top, Normal alkane RI, non-polar column, temperature ramp, References