Propyne

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryPacked
Active phase BPX-5CP Sil 5 CBPoraPLOT QPoraPLOT QSqualane
Column length (m) 12.25.10.10.15.
Carrier gas H2H2H2H2He
Substrate     Chromosorb P
Column diameter (mm) 0.150.150.320.320.25
Phase thickness (μm) 0.252.10.10. 
Temperature (C) 30.20.100.160.27.
I 339.323.6311.316.297.
ReferenceAflalaye, Sternberg, et al., 1995Do and Raulin, 1992Do and Raulin, 1989Do and Raulin, 1989Hively and Hinton, 1968
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPacked
Active phase SqualaneSqualane
Column length (m) 15.10.
Carrier gas He 
Substrate Chromosorb P 
Column diameter (mm) 0.25 
Phase thickness (μm)   
Temperature (C) 86.26.
I 299.340.
ReferenceHively and Hinton, 1968Zulaïca and Guiochon, 1966
Comment MSDC-RI MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Aflalaye, Sternberg, et al., 1995
Aflalaye, A.; Sternberg, R.; Raulin, F.; Vidal-Madjar, C., Gas chromatography of Titan's atmosphere. VI. Analysis of low-molecular-mass hydrocarbons and nitriles with BPX5 capillary columns, J. Chromatogr. A, 1995, 708, 2, 283-291, https://doi.org/10.1016/0021-9673(95)00410-O . [all data]

Do and Raulin, 1992
Do, L.; Raulin, F., Gas chromatography of Titan's atmosphere. III. Analysis of low-molecular-weight hydrocarbons and nitriles with a CP-Sil-5 CB WCOT capillary column, J. Chromatogr., 1992, 591, 1-2, 297-301, https://doi.org/10.1016/0021-9673(92)80247-R . [all data]

Do and Raulin, 1989
Do, L.; Raulin, F., Gas chromatography of Titan's atmosphere. I. Analysis of low-molecular-weight hydrocarbons and nitriles with a PoraPLOT Q porous polymer coated open-tubular capillary column, J. Chromatogr., 1989, 481, 45-54, https://doi.org/10.1016/S0021-9673(01)96751-2 . [all data]

Hively and Hinton, 1968
Hively, R.A.; Hinton, R.E., Variation of the retention index with temperature on squalane substrates, J. Gas Chromatogr., 1968, 6, 4, 203-217, https://doi.org/10.1093/chromsci/6.4.203 . [all data]

Zulaïca and Guiochon, 1966
Zulaïca, J.; Guiochon, G., Analyse des hauts polymères par chromatographie en phase gazeuse de leurs produits de pyrolyse. II. Application à quelques hydrocarbures macromoléculaires purs, Bull. Soc. Chim. Fr., 1966, 4, 1351-1363. [all data]


Notes

Go To: Top, Kovats' RI, non-polar column, isothermal, References