Methanethiol

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type PackedPackedPackedPackedPacked
Active phase SE-30SqualaneSqualaneSqualaneSqualane
Column length (m) 3.2.2.15.15.
Carrier gas    HeHe
Substrate  Chromosorb W DMCSChromosorb W DMCSChromosorb PChromosorb P
Column diameter (mm)    0.250.25
Phase thickness (μm)      
Temperature (C) 42.60.80.27.49.
I 400.401.401.393.396.
ReferenceRudenko, Mal'tsev, et al., 1985Zygmunt and Staszewski, 1981Zygmunt and Staszewski, 1981Hively and Hinton, 1968Hively and Hinton, 1968
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPacked
Active phase SqualaneSqualane
Column length (m) 15.15.
Carrier gas HeHe
Substrate Chromosorb PChromosorb P
Column diameter (mm) 0.250.25
Phase thickness (μm)   
Temperature (C) 67.86.
I 398.401.
ReferenceHively and Hinton, 1968Hively and Hinton, 1968
Comment MSDC-RI MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Rudenko, Mal'tsev, et al., 1985
Rudenko, G.I.; Mal'tsev, V.V.; Studenichnik, V.N.; Ustinov, E.P., Gas chromatographic analysis of volatile substances evolved into atmosphere from polymer materials, Zh. Anal. Khim., 1985, 40, 6, 1119-1127. [all data]

Zygmunt and Staszewski, 1981
Zygmunt, B.; Staszewski, R., Retention index and gas chromatographic-mass spectrometric identification of thiols in liquified gas, Chem. Anal. (Warsaw), 1981, 26, 109-113. [all data]

Hively and Hinton, 1968
Hively, R.A.; Hinton, R.E., Variation of the retention index with temperature on squalane substrates, J. Gas Chromatogr., 1968, 6, 4, 203-217, https://doi.org/10.1093/chromsci/6.4.203 . [all data]


Notes

Go To: Top, Kovats' RI, non-polar column, isothermal, References