Methane, iodo-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type PackedPackedPackedPackedPacked
Active phase OV-1OV-1OV-1ApolaneSqualane
Column length (m) 3.3.3.2.415.
Carrier gas HeHeHeHeHe
Substrate Chromosorb W DMCSChromosorb W DMCSChromosorb W DMCSChromosorbChromosorb P
Column diameter (mm)     0.25
Phase thickness (μm)      
Temperature (C) 100.125.75.70.27.
I 523.528.518.528.6502.
ReferenceCastello and Gerbino, 1988Castello and Gerbino, 1988Castello and Gerbino, 1988Riedo, Fritz, et al., 1976Hively and Hinton, 1968
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPackedPackedPackedPacked
Active phase SqualaneSqualaneSqualaneDC-200Squalane
Column length (m) 15.15.15.4.5.
Carrier gas HeHeHe  
Substrate Chromosorb PChromosorb PChromosorb P  
Column diameter (mm) 0.250.250.25  
Phase thickness (μm)      
Temperature (C) 49.67.86.100.100.
I 508.513.518.524.516.
ReferenceHively and Hinton, 1968Hively and Hinton, 1968Hively and Hinton, 1968Rohrschneider, 1966Rohrschneider, 1966
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type Packed
Active phase Apiezon L
Column length (m) 5.
Carrier gas  
Substrate  
Column diameter (mm)  
Phase thickness (μm)  
Temperature (C) 100.
I 554.
ReferenceRohrschneider, 1966
Comment MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Castello and Gerbino, 1988
Castello, G.; Gerbino, T.C., Effect of Temperature on the Gas Chromatographic Separation of Halogenated Compounds on Polar and Non-Polar Stationary Phases, J. Chromatogr., 1988, 437, 33-45, https://doi.org/10.1016/S0021-9673(00)90369-8 . [all data]

Riedo, Fritz, et al., 1976
Riedo, F.; Fritz, D.; Tarján, G.; Kováts, E.Sz., A tailor-made C87 hydrocarbon as a possible non-polar standard stationary phase for gas chromatography, J. Chromatogr., 1976, 126, 63-83, https://doi.org/10.1016/S0021-9673(01)84063-2 . [all data]

Hively and Hinton, 1968
Hively, R.A.; Hinton, R.E., Variation of the retention index with temperature on squalane substrates, J. Gas Chromatogr., 1968, 6, 4, 203-217, https://doi.org/10.1093/chromsci/6.4.203 . [all data]

Rohrschneider, 1966
Rohrschneider, L., Eine methode zur charakterisierung von gaschromatographischen trennflüssigkeiten, J. Chromatogr., 1966, 22, 6-22, https://doi.org/10.1016/S0021-9673(01)97064-5 . [all data]


Notes

Go To: Top, Kovats' RI, non-polar column, isothermal, References