1-Butanol

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, non-polar column, custom temperature program

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase BP-1BP-5BPX-5Petrocol DH-100SPB-1
Column length (m)    100.60.
Carrier gas    HeN2
Substrate      
Column diameter (mm)    0.20.75
Phase thickness (μm)      
Program not specifiednot specifiednot specified5C(10min) => 5C/min => 50C(48min) => 1.5C/min => 195C(91min)not specified
I 646.665.667.650.05658.7
ReferenceSGE, 2005SGE, 2005SGE, 2005Haagen-Smit Laboratory, 1997Castello, Timossi, et al., 1988
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedCapillaryCapillaryPacked
Active phase Apiezon LSE-30SE-30SE-30
Column length (m) 1.280.80.2.
Carrier gas     
Substrate Chromosorb W HMDS HP (00-120 mesh)  Chromosrb G
Column diameter (mm)  0.290.29 
Phase thickness (μm)     
Program not specifiednot specifiednot specifiednot specified
I 680.686.688.690.
ReferenceRasmussen, 1983Brander, Kepner, et al., 1980Brander, Kepner, et al., 1980Moffat, Stead, et al., 1974
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, custom temperature program, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

SGE, 2005
SGE, Guide to GC column selection, 2005, retrieved from http://www.sge.com/htm/support/productselection/prodselgc.asp. [all data]

Haagen-Smit Laboratory, 1997
Haagen-Smit Laboratory, Procedure for the detailed hydrocarbon analysis of gasolines by single column high efficiency (capillary) column gas chromatography, SOP NO. MLD 118, Revision No. 1.1, California Environmental Protection Agency, Air Resources Board, El Monte, California, 1997, 22. [all data]

Castello, Timossi, et al., 1988
Castello, G.; Timossi, A.; Gerbino, T.C., Gas Chromatographic Separation of Halogenated Compounds on Non-Polar and Polar Wide Bore Capillary Columns, J. Chromatogr., 1988, 454, 129-143, https://doi.org/10.1016/S0021-9673(00)88608-2 . [all data]

Rasmussen, 1983
Rasmussen, P., Identification of Volatile Components of Jacjfruit by Gas Chromatography / MAss Spectrometry with Two Different Columns, Anal. Chem., 1983, 55, 8, 1331-1335, https://doi.org/10.1021/ac00259a033 . [all data]

Brander, Kepner, et al., 1980
Brander, C.F.; Kepner, R.E.; Webb, A.D., Identification of Some Volatile Compounds of Wine of Vitis Vinifera Cultivar Pinot Noir, Am. J. Enol. Vitic, 1980, 31, 1, 69-75. [all data]

Moffat, Stead, et al., 1974
Moffat, A.C.; Stead, A.H.; Smalldon, K.W., Optimum use of paper, thin-layer and gas-liquid chromatography for the identification of basic drugs. III. Gas-liquid chromatography, J. Chromatogr., 1974, 90, 1, 19-33, https://doi.org/10.1016/S0021-9673(01)94770-3 . [all data]


Notes

Go To: Top, Kovats' RI, non-polar column, custom temperature program, References