1-Propanol

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Van Den Dool and Kratz RI, polar column, custom temperature program

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase Supelcowax-10Supelcowax-10Supelcowax-10Supelcowax-10Supelcowax-10
Column length (m) 30.30.30.30.30.
Carrier gas  HeHeHeHe
Substrate      
Column diameter (mm) 0.250.250.250.250.25
Phase thickness (μm) 0.250.250.250.250.25
Program 35C(8min) => 4C/min => 60C => 6C/min => 160C => 20C/min => 220C(1min)35C(8min) => 4C/min => 60C => 6C/min => 160C => 20C/min => 200C(1min)35C(8min) => 4C/min => 60C => 6C/min => 160C => 20C/min => 200C(1min)35C(8min) => 4C/min => 60C => 6C/min => 160C => 20C/min => 200C(1min)35C(8min) => 4C/min => 60C => 6C/min => 160C => 20C/min => 200C(1min)
I 1052.1052.1051.1052.1052.
ReferenceBianchi, Cantoni, et al., 2007Bianchi, Careri, et al., 2007Bianchi, Careri, et al., 2007Bianchi, Careri, et al., 2007Bianchi, Careri, et al., 2007
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase DB-WaxDB-WaxSupelcowax-10DB-WaxDB-Wax
Column length (m) 30.60.30.30.30.
Carrier gas H2He HeHe
Substrate      
Column diameter (mm) 0.320.250.320.320.32
Phase thickness (μm) 0.50.250.30.50.5
Program 60C(3min) => 2C/min => 220C => 3C/min => 245C (20min)35C(0.7min) => 20C/min => 70C => 4C/min => 240C60C(8min) => 8C/min => 170C => 13C/min => 240C(20min)50C => 5C/min => 180C => 10C/min => 250C50C => 5C/min => 180C => 10C/min => 250C
I 1037.1029.1041.1032.1034.
ReferenceSelli, Canbas, et al., 2006Ferrari, Lablanquie, et al., 2004da Porto, Pizzale, et al., 2003Sérot, Regost, et al., 2002Sérot, Regost, et al., 2001
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type Capillary
Active phase FFAP
Column length (m) 50.
Carrier gas He
Substrate  
Column diameter (mm) 0.25
Phase thickness (μm) 0.25
Program 20C (5min) => 2C/min => 70C => 4C/min => 210C
I 1031.
ReferenceYasuhara, 1987
Comment MSDC-RI

References

Go To: Top, Van Den Dool and Kratz RI, polar column, custom temperature program, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Bianchi, Cantoni, et al., 2007
Bianchi, F.; Cantoni, C.; Careri, M.; Chiesa, L.; Musci, M.; Pinna, A., Characterization of the aromatic profile for the authentication and differentiation of typical Italian dry-sausages, Talanta, 2007, 72, 4, 1552-1563, https://doi.org/10.1016/j.talanta.2007.02.019 . [all data]

Bianchi, Careri, et al., 2007
Bianchi, F.; Careri, M.; Mangia, A.; Musci, M., Retention indices in the analysis of food aroma volatile compounds in temperature-programmed gas chromatography: Database creation and evaluation of precision and robustness, J. Sep. Sci., 2007, 39, 4, 563-572, https://doi.org/10.1002/jssc.200600393 . [all data]

Selli, Canbas, et al., 2006
Selli, S.; Canbas, A.; Cabaroglu, T.; Erten, H.; Gunata, Z., Aroma components of cv. Muscat of Bornova wines and influence of skin contact treatment, Food Chem., 2006, 94, 3, 319-326, https://doi.org/10.1016/j.foodchem.2004.11.019 . [all data]

Ferrari, Lablanquie, et al., 2004
Ferrari, G.; Lablanquie, O.; Cantagrel, R.; Ledauphin, J.; Payot, T.; Fournier, N.; Guichard, E., Determination of key odorant compounds in freshly distilled cognac using GC-O, GC-MS, and sensory evaluation, J. Agric. Food Chem., 2004, 52, 18, 5670-5676, https://doi.org/10.1021/jf049512d . [all data]

da Porto, Pizzale, et al., 2003
da Porto, C.; Pizzale, L.; Bravin, M.; Conte, L.S., Analyses of orange spirit flavour by direct-injection gas chromatography-mass spectrometry and headspace solid-phase microextraction/GC-MC, Flavour Fragr. J., 2003, 18, 1, 66-72, https://doi.org/10.1002/ffj.1164 . [all data]

Sérot, Regost, et al., 2002
Sérot, T.; Regost, C.; Arzel, J., Identification of odour-active compounds in muscle of brown trout (Salmo trutta) as affected by dietary lipid sources, J. Sci. Food Agric., 2002, 82, 6, 636-643, https://doi.org/10.1002/jsfa.1096 . [all data]

Sérot, Regost, et al., 2001
Sérot, T.; Regost, C.; Prost, C.; Robin, J.; Arzel, J., Effect of dietary lipid sources on odour-active compounds in muscle of turbot (Psetta maxima), J. Sci. Food Agric., 2001, 81, 14, 1339-1346, https://doi.org/10.1002/jsfa.950 . [all data]

Yasuhara, 1987
Yasuhara, A., Identification of Volatile Compounds in Poultry Manure by Gas Chromatography-Mass Spectrometry, J. Chromatogr., 1987, 387, 371-378, https://doi.org/10.1016/S0021-9673(01)94539-X . [all data]


Notes

Go To: Top, Van Den Dool and Kratz RI, polar column, custom temperature program, References