2(3H)-Furanone, 5-ethyldihydro-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Van Den Dool and Kratz RI, polar column, custom temperature program

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase SOLGel-WaxSOLGel-WaxSOLGel-WaxDB-WaxDB-Wax
Column length (m) 30.30.30.30.30.
Carrier gas HeHeHeH2H2
Substrate      
Column diameter (mm) 0.250.250.250.250.25
Phase thickness (μm) 0.250.250.250.250.25
Program 35C(5min) => 3C/min => 150C => 5C/min => 250C(10 min)35C(5min) => 3C/min => 150C => 5C/min => 250C (10min)35C(5min) => 3C/min => 150C => 5C/min => 250C (10min)60C (3min) => 2C/min => 220C => 5C/min => 250C (15min)60C (3min) => 2C/min => 220C => 5C/min => 250C (15min)
I 1661.1661.1661.1679.1673.
ReferenceAubert, Baumann, et al., 2005Aubert, Baumann, et al., 2005Aubert, Baumann, et al., 2005Boulanger and Crouzet, 2001Boulanger and Crouzet, 2001
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillary
Active phase DB-WaxFFAP
Column length (m) 30.30.
Carrier gas  He
Substrate   
Column diameter (mm) 0.250.32
Phase thickness (μm) 0.250.25
Program 20C(30s) => fast => 60C => 4C/min => 220C (20min)35C (2min) => 40C/min => 60C => 4C/min => 230C (10min)
I 1678.1698.
ReferenceCantergiani, Brevard, et al., 2001Derail, Hofmann, et al., 1999
Comment MSDC-RI MSDC-RI

References

Go To: Top, Van Den Dool and Kratz RI, polar column, custom temperature program, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Aubert, Baumann, et al., 2005
Aubert, C.; Baumann, S.; Arguel, H., Optimization of the Analysis of Flavor Volatile Compounds by Liquid-Liquid Microextraction (LLME). Application to the Aroma Analysis of Melons, Peaches, Grapes, Strawberries, and Tomatoes, J. Agric. Food Chem., 2005, 53, 23, 8881-8895, https://doi.org/10.1021/jf0510541 . [all data]

Boulanger and Crouzet, 2001
Boulanger, R.; Crouzet, J., Identification of the aroma components of acerola (Malphigia glabra L.): free and bound flavor compounds, Food Chem., 2001, 74, 2, 209-216, https://doi.org/10.1016/S0308-8146(01)00128-5 . [all data]

Cantergiani, Brevard, et al., 2001
Cantergiani, E.; Brevard, H.; Krebs, Y.; Feria-Morales, A.; Amadò, R.; Yeretzian, C., Characterisation of the aroma of green Mexican coffee and identification of mouldy/earthy defect, Eur. Food Res. Technol., 2001, 212, 6, 648-657, https://doi.org/10.1007/s002170100305 . [all data]

Derail, Hofmann, et al., 1999
Derail, C.; Hofmann, T.; Schieberle, P., Differences in key odorants of handmade juice of yellow-flesh peaches (Prunus persica L.) induced by the workup procedure, J. Agric. Food Chem., 1999, 47, 11, 4742-4745, https://doi.org/10.1021/jf990459g . [all data]


Notes

Go To: Top, Van Den Dool and Kratz RI, polar column, custom temperature program, References