1-Hexyne

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type PackedPackedPackedCapillaryCapillary
Active phase C78, Branched paraffinC78, Branched paraffinApolaneSqualaneSqualane
Column length (m) 3.33.33.7107.100.
Carrier gas He  H2N2
Substrate  Chromosorb G HP   
Column diameter (mm)    0.250.25
Phase thickness (μm)    0.40 
Temperature (C) 130.130.130.80.100.
I 587.3588.2590.583.584.
ReferenceDallos, Sisak, et al., 2000Reddy, Dutoit, et al., 1992Dutoit, 1991Soják, Farkas, et al., 1991Rang, Kuningas, et al., 1976
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase SqualaneSqualaneSqualaneSqualaneSqualane
Column length (m) 100.100.100.100.100.
Carrier gas N2N2N2N2N2
Substrate      
Column diameter (mm) 0.250.250.250.250.25
Phase thickness (μm)      
Temperature (C) 110.120.130.86.90.
I 584.584.584.587.584.
ReferenceRang, Kuningas, et al., 1976Rang, Kuningas, et al., 1976Rang, Kuningas, et al., 1976Rang, Kuningas, et al., 1976Rang, Kuningas, et al., 1976
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedCapillaryPackedPackedPacked
Active phase ApolaneSqualaneSqualaneSqualaneSqualane
Column length (m) 2.480.15.15.15.
Carrier gas He HeHeHe
Substrate Chromosorb Chromosorb PChromosorb PChromosorb P
Column diameter (mm)  0.250.250.250.25
Phase thickness (μm)      
Temperature (C) 70.60.27.49.67.
I 587.3588.586.586.587.
ReferenceRiedo, Fritz, et al., 1976Orav and Eisen, 1972Hively and Hinton, 1968Hively and Hinton, 1968Hively and Hinton, 1968
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type Packed
Active phase Squalane
Column length (m) 15.
Carrier gas He
Substrate Chromosorb P
Column diameter (mm) 0.25
Phase thickness (μm)  
Temperature (C) 86.
I 587.
ReferenceHively and Hinton, 1968
Comment MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Dallos, Sisak, et al., 2000
Dallos, A.; Sisak, A.; Kulcsár, Z.; Kováts, E., Pair-wise interactions by gas chromatography VII. Interaction free enthalpies of solutes with secondary alcohol groups, J. Chromatogr. A, 2000, 904, 2, 211-242, https://doi.org/10.1016/S0021-9673(00)00908-0 . [all data]

Reddy, Dutoit, et al., 1992
Reddy, K.S.; Dutoit, J.-Cl.; Kovats, E. sz., Pair-wise interactions by gas chromatography. I. Interaction free enthalpies of solutes with non-associated primary alcohol groups, J. Chromatogr., 1992, 609, 1-2, 229-259, https://doi.org/10.1016/0021-9673(92)80167-S . [all data]

Dutoit, 1991
Dutoit, J., Gas chromatographic retention behaviour of some solutes on structurally similar polar and non-polar stationary phases, J. Chromatogr., 1991, 555, 1-2, 191-204, https://doi.org/10.1016/S0021-9673(01)87179-X . [all data]

Soják, Farkas, et al., 1991
Soják, L.; Farkas, P.; Ostrovský, I.; Janák, J.; Chrétien, J.R., Capillary gas chromatography of C5 - C13 branched alkynes on squalane and liquid crystal stationary phases, J. Chromatogr., 1991, 557, 241-253, https://doi.org/10.1016/S0021-9673(01)87136-3 . [all data]

Rang, Kuningas, et al., 1976
Rang, S.; Kuningas, K.; Orav, A.; Eisen, O., Capillary gas chromatography of n-alkynes. I. Retention indices, J. Chromatogr., 1976, 119, 451-460, https://doi.org/10.1016/S0021-9673(00)86807-7 . [all data]

Riedo, Fritz, et al., 1976
Riedo, F.; Fritz, D.; Tarján, G.; Kováts, E.Sz., A tailor-made C87 hydrocarbon as a possible non-polar standard stationary phase for gas chromatography, J. Chromatogr., 1976, 126, 63-83, https://doi.org/10.1016/S0021-9673(01)84063-2 . [all data]

Orav and Eisen, 1972
Orav, A.; Eisen, O., The retention indexes for alkenes, alkynes and cyclenes on capillary columns, Izv. Akad. Nauk Est. SSR, Khim. Geol., 1972, 21, 1, 39-47. [all data]

Hively and Hinton, 1968
Hively, R.A.; Hinton, R.E., Variation of the retention index with temperature on squalane substrates, J. Gas Chromatogr., 1968, 6, 4, 203-217, https://doi.org/10.1093/chromsci/6.4.203 . [all data]


Notes

Go To: Top, Kovats' RI, non-polar column, isothermal, References