3-Hexene, 2,5-dimethyl-, (E)-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase Petrocol DHSqualaneOV-101OV-101OV-101
Column length (m) 150.93.   
Carrier gas H2He   
Substrate      
Column diameter (mm) 0.250.25   
Phase thickness (μm) 1.    
Temperature (C) 30.30.40.60.80.
I 713.6695.5704.703.703.
ReferenceSoják, Addová, et al., 2004Soják, Addová, et al., 2004Laub and Purnell, 1988Laub and Purnell, 1988Laub and Purnell, 1988
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase OV-101OV-101SqualaneSqualaneSqualane
Column length (m) 100.100.100.100. 
Carrier gas N2N2N2N2 
Substrate      
Column diameter (mm) 0.270.270.250.25 
Phase thickness (μm) 0.90.9   
Temperature (C) 50.70.50.70.50.
I 703.7703.2695.694.5695.
ReferenceBoneva and Dimov, 1986Boneva and Dimov, 1986Boneva and Dimov, 1986Boneva and Dimov, 1986Chretien and Dubois, 1976
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillary
Active phase SqualaneSqualaneSqualane
Column length (m) 100.100.91.4
Carrier gas N2N2N2
Substrate    
Column diameter (mm) 0.250.250.25
Phase thickness (μm)    
Temperature (C) 50.70.40.
I 695.695.696.
ReferenceRijks and Cramers, 1974Rijks and Cramers, 1974Matukuma, 1969
Comment MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Soják, Addová, et al., 2004
Soják, L.; Addová, G.; Kubinec, R.; Kraus, A.; Bohác, A., Capillary gas chromatography-mass spectrometry of all 93 acyclic octenes and their identification in fluid catalytic cracked gasoline, J. Chromatogr. A, 2004, 1025, 2, 237-253, https://doi.org/10.1016/j.chroma.2003.10.112 . [all data]

Laub and Purnell, 1988
Laub, R.J.; Purnell, J.H., Specific retention volumes, retention indices, and family-plot regressions of aliphatic, alicyclic, and aromatic hydrocarbon solutes with OV-101 poly (dimethylsiloxane) stationary phase, J. Hi. Res. Chromatogr. Chromatogr. Comm., 1988, 11, 9, 649-660, https://doi.org/10.1002/jhrc.1240110908 . [all data]

Boneva and Dimov, 1986
Boneva, S.; Dimov, N., Gas Chromatographic Retention Indices for Alkenes on OV-101 and Squalane Capillary Columns, Chromatographia, 1986, 21, 3, 149-151, https://doi.org/10.1007/BF02311743 . [all data]

Chretien and Dubois, 1976
Chretien, J.R.; Dubois, J.-E., New Perspectives in the Prediction of Kovats Indices, J. Chromatogr., 1976, 126, 171-189, https://doi.org/10.1016/S0021-9673(01)84071-1 . [all data]

Rijks and Cramers, 1974
Rijks, J.A.; Cramers, C.A., High precision capillary gas chromatography of hydrocarbons, Chromatographia, 1974, 7, 3, 99-106, https://doi.org/10.1007/BF02269819 . [all data]

Matukuma, 1969
Matukuma, A., Retention indices of alkanes through C10 and alkenes through C8 and relation between boiling points and retention data, Gas Chromatogr., Int. Symp. Anal. Instrum. Div Instrum Soc. Amer., 1969, 7, 55-75. [all data]


Notes

Go To: Top, Kovats' RI, non-polar column, isothermal, References