Acetone

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Normal alkane RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase Methyl SiliconeMethyl SiliconeMethyl SiliconeMethyl SiliconeDB-1
Column length (m)     60.
Carrier gas     He
Substrate      
Column diameter (mm)     0.32
Phase thickness (μm)     1.
Temperature (C) 100.120.140.80.60.
I 471.480.472.473.472.
ReferenceLebrón-Aguilar, Quintanilla-López, et al., 2007Lebrón-Aguilar, Quintanilla-López, et al., 2007Lebrón-Aguilar, Quintanilla-López, et al., 2007Lebrón-Aguilar, Quintanilla-López, et al., 2007Shimadzu, 2003
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryPackedPackedPacked
Active phase OV-1SynachromSynachromDC-400
Column length (m)  1.51.53.0
Carrier gas  HeliumHeliumHelium
Substrate  Synachrom (60-80 mesh)Synachrom (60-80 mesh)Gas-Pak (60-80 mesh)
Column diameter (mm)     
Phase thickness (μm)     
Temperature (C) 60.150.150.150.
I 470.466.468.466.
ReferenceAmboni, Junkes, et al., 2002Dufka, Malinsky, et al., 1971Dufka, Malinsky, et al., 1971Anderson, 1968
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Normal alkane RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Lebrón-Aguilar, Quintanilla-López, et al., 2007
Lebrón-Aguilar, R.; Quintanilla-López, J.E.; Tello, A.M.; Santiuste, J.M., Isothermal retention indices on poly (3,3,3-trifluoropropylmethylsiloxane) stationary phases, J. Chromatogr. A, 2007, 1160, 1-2, 276-288, https://doi.org/10.1016/j.chroma.2007.05.025 . [all data]

Shimadzu, 2003
Shimadzu, Gas chromatography analysis of organic solvents using capillary columns (No. 3), 2003, retrieved from http://www.shimadzu.com/apps/form.cfm. [all data]

Amboni, Junkes, et al., 2002
Amboni, R.D.DeM.C.; Junkes, B. daS.; Yunes, R.A.; Heinzen, V.E.F., Quantitative structure-property relationships study of chromatographic retention indices and normal boiling points for oxo compounds using the semi-empirical topological method, J. Mol. Struct. (Theochem), 2002, 586, 1-3, 71-80, https://doi.org/10.1016/S0166-1280(02)00062-3 . [all data]

Dufka, Malinsky, et al., 1971
Dufka, O.; Malinsky, J.; Vladyka, J., Sorpcni materialy pro plynovou chromatographii - III, Chemicky promysl., 1971, 21/46, 9, 459-463. [all data]

Anderson, 1968
Anderson, D.G., USe of Kovats retention indices and response factors for the qualitative and quantitative analysis of coating solvents, J. Paint Technol., 1968, 40, 527, 549-557. [all data]


Notes

Go To: Top, Normal alkane RI, non-polar column, isothermal, References