Hexane, 1-nitro-
- Formula: C6H13NO2
- Molecular weight: 131.1729
- IUPAC Standard InChIKey: FEYJIFXFOHFGCC-UHFFFAOYSA-N
- CAS Registry Number: 646-14-0
- Chemical structure:
This structure is also available as a 2d Mol file or as a computed 3d SD file
The 3d structure may be viewed using Java or Javascript. - Other names: Nitrohexane; 1-Nitrohexane
- Permanent link for this species. Use this link for bookmarking this species for future reference.
- Information on this page:
- Options:
Data at NIST subscription sites:
NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.
Phase change data
Go To: Top, Mass spectrum (electron ionization), Gas Chromatography, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: Robert L. Brown and Stephen E. Stein
Reduced pressure boiling point
Tboil (K) | Pressure (bar) | Reference |
---|---|---|
364.7 | 0.032 | Aldrich Chemical Company Inc., 1990 |
Mass spectrum (electron ionization)
Go To: Top, Phase change data, Gas Chromatography, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Spectrum
Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.
Additional Data
View image of digitized spectrum (can be printed in landscape orientation).
Due to licensing restrictions, this spectrum cannot be downloaded.
Owner | NIST Mass Spectrometry Data Center Collection (C) 2014 copyright by the U.S. Secretary of Commerce on behalf of the United States of America. All rights reserved. |
---|---|
Origin | Japan AIST/NIMC Database- Spectrum MS-NW-7413 |
NIST MS number | 238163 |
Gas Chromatography
Go To: Top, Phase change data, Mass spectrum (electron ionization), References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Kovats' RI, non-polar column, isothermal
Column type | Active phase | Temperature (C) | I | Reference | Comment |
---|---|---|---|---|---|
Capillary | HP-1 | 100. | 1011.7 | Görgényi and Héberger, 2003 | N2; Column length: 30. m; Phase thickness: 1.05 μm |
Capillary | HP-1 | 110. | 1013.6 | Görgényi and Héberger, 2003 | N2; Column length: 30. m; Phase thickness: 1.05 μm |
Capillary | HP-1 | 120. | 1015.4 | Görgényi and Héberger, 2003 | N2; Column length: 30. m; Phase thickness: 1.05 μm |
Capillary | HP-1 | 30. | 1001.2 | Görgényi and Héberger, 2003 | N2; Column length: 30. m; Phase thickness: 1.05 μm |
Capillary | HP-1 | 40. | 1003.5 | Görgényi and Héberger, 2003 | N2; Column length: 30. m; Phase thickness: 1.05 μm |
Capillary | HP-1 | 50. | 1004.4 | Görgényi and Héberger, 2003 | N2; Column length: 30. m; Phase thickness: 1.05 μm |
Capillary | HP-1 | 60. | 1005.8 | Görgényi and Héberger, 2003 | N2; Column length: 30. m; Phase thickness: 1.05 μm |
Capillary | HP-1 | 70. | 1006.6 | Görgényi and Héberger, 2003 | N2; Column length: 30. m; Phase thickness: 1.05 μm |
Capillary | HP-1 | 80. | 1008.4 | Görgényi and Héberger, 2003 | N2; Column length: 30. m; Phase thickness: 1.05 μm |
Capillary | HP-1 | 90. | 1010. | Görgényi and Héberger, 2003 | N2; Column length: 30. m; Phase thickness: 1.05 μm |
Capillary | DB-1MS | 90. | 1009.7 | Vickers, Kuhn, et al., 2003 | 30. m/0.25 mm/0.25 μm, He |
Capillary | DB-1 | 90. | 1009.4 | Vickers, Kuhn, et al., 2003 | 30. m/0.25 mm/0.25 μm, He |
Capillary | DB-5 | 140. | 1057.28 | Hobbs and Conde, 1992 | 30. m/0.25 mm/0.25 μm |
Packed | Apolane | 130. | 970. | Dutoit, 1991 | Column length: 3.7 m |
Packed | Apiezon L | 100. | 992. | Brown, Chapman, et al., 1968 | N2, DCMS-treated Chromosorb W; Column length: 2.3 m |
Packed | Apiezon L | 150. | 1008. | Brown, Chapman, et al., 1968 | N2, DCMS-treated Chromosorb W; Column length: 2.3 m |
Kovats' RI, polar column, isothermal
Column type | Active phase | Temperature (C) | I | Reference | Comment |
---|---|---|---|---|---|
Capillary | HP-Innowax | 100. | 1527.3 | Görgényi and Héberger, 2003 | Column length: 30. m; Phase thickness: 0.5 μm |
Capillary | HP-Innowax | 110. | 1530.5 | Görgényi and Héberger, 2003 | Column length: 30. m; Phase thickness: 0.5 μm |
Capillary | HP-Innowax | 120. | 1533.4 | Görgényi and Héberger, 2003 | Column length: 30. m; Phase thickness: 0.5 μm |
Capillary | HP-Innowax | 50. | 1502.5 | Görgényi and Héberger, 2003 | Column length: 30. m; Phase thickness: 0.5 μm |
Capillary | HP-Innowax | 60. | 1506.9 | Görgényi and Héberger, 2003 | Column length: 30. m; Phase thickness: 0.5 μm |
Capillary | HP-Innowax | 70. | 1511.8 | Görgényi and Héberger, 2003 | Column length: 30. m; Phase thickness: 0.5 μm |
Capillary | HP-Innowax | 80. | 1516.8 | Görgényi and Héberger, 2003 | Column length: 30. m; Phase thickness: 0.5 μm |
Capillary | HP-Innowax | 90. | 1521.6 | Görgényi and Héberger, 2003 | Column length: 30. m; Phase thickness: 0.5 μm |
Van Den Dool and Kratz RI, non-polar column, temperature ramp
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | HP-5 | 1050. | Solina, Baumgartner, et al., 2005 | 25. m/0.2 mm/1. μm, He, 5. K/min, 280. C @ 5. min; Tstart: 40. C |
Capillary | DB-5 | 1034.63 | Hobbs and Conde, 1992 | 30. m/0.25 mm/0.25 μm, 5. K/min; Tstart: 40. C; Tend: 300. C |
Capillary | DB-5 | 1046.47 | Hobbs and Conde, 1992 | 30. m/0.25 mm/0.25 μm, 5. K/min; Tstart: 40. C; Tend: 300. C |
References
Go To: Top, Phase change data, Mass spectrum (electron ionization), Gas Chromatography, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Aldrich Chemical Company Inc., 1990
Aldrich Chemical Company Inc.,
Catalog Handbook of Fine Chemicals, Aldrich Chemical Company, Inc., Milwaukee WI, 1990, 1. [all data]
Görgényi and Héberger, 2003
Görgényi, M.; Héberger, K.,
Minimum in the temperature dependence of the Kováts retention indices of nitroalkanes and alkanenitriles on an apolar phase,
J. Chromatogr. A, 2003, 985, 1-2, 11-19, https://doi.org/10.1016/S0021-9673(02)01842-3
. [all data]
Vickers, Kuhn, et al., 2003
Vickers, A.K.; Kuhn, E.; Lautamo, R.,
A novel, inert, low bleed column for GC-MS, 2003, retrieved from http://www.chem.agilent.com/cag/cabu/gcapps.htm. [all data]
Hobbs and Conde, 1992
Hobbs, J.R.; Conde, E.P.,
Gas chromatographic retention indices of explosives and nitro-compounds
in Advances in Analysis and Detection of Explosives: Proceedings of the 4th International Symposium on Analysis of Detection of Explosives, September 7-10, 1992, Jerusalem Israel, J. Yinon, ed(s)., Kluwer Academic Publishers, Netherlands, 1992, 153-164. [all data]
Dutoit, 1991
Dutoit, J.,
Gas chromatographic retention behaviour of some solutes on structurally similar polar and non-polar stationary phases,
J. Chromatogr., 1991, 555, 1-2, 191-204, https://doi.org/10.1016/S0021-9673(01)87179-X
. [all data]
Brown, Chapman, et al., 1968
Brown, I.; Chapman, I.L.; Nicholson, G.J.,
Gas chromatography of polar solutes in electron acceptor stationary phases,
Aust. J. Chem., 1968, 21, 5, 1125-1141, https://doi.org/10.1071/CH9681125
. [all data]
Solina, Baumgartner, et al., 2005
Solina, M.; Baumgartner, P.; Johnson, R.L.; Whitfield, F.B.,
Volatile aroma components of soy protein isolate and acid-hydrolysed vegetable protein,
Food Chem., 2005, 90, 4, 861-873, https://doi.org/10.1016/j.foodchem.2004.06.005
. [all data]
Notes
Go To: Top, Phase change data, Mass spectrum (electron ionization), Gas Chromatography, References
- Symbols used in this document:
Tboil Boiling point - Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.
- Customer support for NIST Standard Reference Data products.