2-Pentene, (E)-
- Formula: C5H10
- Molecular weight: 70.1329
- IUPAC Standard InChIKey: QMMOXUPEWRXHJS-HWKANZROSA-N
- CAS Registry Number: 646-04-8
- Chemical structure:
This structure is also available as a 2d Mol file or as a computed 3d SD file
View 3d structure (requires JavaScript / HTML 5) - Stereoisomers:
- Other names: trans-2-Pentene; (E)-2-Pentene; trans-β-Amylene; 2-trans-Pentene; 2-(E)-C5H10; 2-Pentene, trans-; Pentene-2, trans-; trans-pent-2-ene
- Permanent link for this species. Use this link for bookmarking this species for future reference.
- Information on this page:
- Other data available:
- Data at other public NIST sites:
- Options:
Data at NIST subscription sites:
NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.
Normal alkane RI, non-polar column, custom temperature program
Go To: Top, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Column type | Capillary | Capillary | Capillary | Capillary | Capillary |
---|---|---|---|---|---|
Active phase | Polydimethyl siloxane | PONA | DB-1 | CP-Sil5 CB MS | Methyl Silicone |
Column length (m) | 100. | 50. | |||
Carrier gas | |||||
Substrate | |||||
Column diameter (mm) | 0.32 | ||||
Phase thickness (μm) | 0.50 | 0.4 | |||
Program | not specified | not specified | not specified | 0C (3min) => 3C/min => 50C => 5C/min => 220C (30min) | not specified |
I | 500. | 511. | 507. | 506. | 509. |
Reference | Junkes, Castanho, et al., 2003 | Perkin Elmer Instruments, 2002 | Zhu and Wang, 2001 | Tirillini, Verdelli, et al., 2000 | Spieksma, 1999 |
Comment | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI |
Column type | Capillary | Capillary | Capillary | Capillary | Capillary |
---|---|---|---|---|---|
Active phase | OV-1 | OV-1 | SE-54 | SE-54 | Methyl Silicone |
Column length (m) | |||||
Carrier gas | |||||
Substrate | |||||
Column diameter (mm) | |||||
Phase thickness (μm) | |||||
Program | not specified | not specified | not specified | not specified | not specified |
I | 506. | 507. | 509. | 511. | 507. |
Reference | Zhu and He, 1999 | Zhu and He, 1999 | Zhu and He, 1999 | Zhu and He, 1999 | Zenkevich, 1996 |
Comment | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI |
Column type | Capillary | Packed | Packed |
---|---|---|---|
Active phase | DB-1 | SE-30 | Squalane |
Column length (m) | 60. | 6.1 | 3.0 |
Carrier gas | N2 | N2 | |
Substrate | Chromosorb W | Embacel | |
Column diameter (mm) | 0.32 | ||
Phase thickness (μm) | 0.25 | ||
Program | not specified | 50C910min) => 20C/min => 90(6min) => 10C/min => 150C(hold) | 25C(5min) => 2C/min => 35 => 4C/min => 95C(hold) |
I | 505. | 512. | 500. |
Reference | Ciccioli, Cecinato, et al., 1994 | Robinson and Odell, 1971 | Robinson and Odell, 1971 |
Comment | MSDC-RI | MSDC-RI | MSDC-RI |
References
Go To: Top, Normal alkane RI, non-polar column, custom temperature program, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Junkes, Castanho, et al., 2003
Junkes, B.S.; Castanho, R.D.M.; Amboni, C.; Yunes, R.A.; Heinzen, V.E.F.,
Semiempirical Topological Index: A Novel Molecular Descriptor for Quantitative Structure-Retention Relationship Studies,
Internet Electronic Journal of Molecular Design, 2003, 2, 1, 33-49. [all data]
Perkin Elmer Instruments, 2002
Perkin Elmer Instruments,
Detailed hydrocarbon analysis (DHAX) Model 4015, 2002, retrieved from http://www.perkinelmer.com/instruments. [all data]
Zhu and Wang, 2001
Zhu, X.; Wang, W.,
The relationship between partition coefficients of hydrocarbons and their retention indices,
Acta Scientific Circumstantiae, 2001, 21, 5, 631-633. [all data]
Tirillini, Verdelli, et al., 2000
Tirillini, B.; Verdelli, G.; Paolocci, F.; Ciccioli, P.; Frattoni, M.,
The volatile organic compounds from the mycelium of Tuber borchii Vitt.,
Phytochemistry, 2000, 55, 8, 983-985, https://doi.org/10.1016/S0031-9422(00)00308-3
. [all data]
Spieksma, 1999
Spieksma, W.,
Determination of vapor liquid equilibrium from the Kovats retention index on dimethylsilicone using the Wilson mixing tool,
J. Hi. Res. Chromatogr., 1999, 22, 10, 565-588, https://doi.org/10.1002/(SICI)1521-4168(19991001)22:10<565::AID-JHRC565>3.0.CO;2-2
. [all data]
Zhu and He, 1999
Zhu, X.; He, L.,
Derivation of isothermal retention indices from a retention values under multiple-ramp temperature-programmed conditions,
J. Instrum. Anal. (Chinese), 1999, 18, 6, 10-12. [all data]
Zenkevich, 1996
Zenkevich, I.G.,
Informational Maitenance of Gas Chromatographic Identification of Organic Compounds in Ecoanalytical Investigations,
Z. Anal. Chem., 1996, 51, 11, 1140-1148. [all data]
Ciccioli, Cecinato, et al., 1994
Ciccioli, P.; Cecinato, A.; Brancaleoni, E.; Brachetti, A.; Frattoni, M.; Sparapani, R.,
Composition and Distribution of Polar and Non-Polar VOCs in Urban, Rural, Forest and Remote Areas,
Eur Commission EUR, 1994, 549-568. [all data]
Robinson and Odell, 1971
Robinson, P.G.; Odell, A.L.,
A system of standard retention indices and its uses. The characterisation of stationary phases and the prediction of retention indices,
J. Chromatogr., 1971, 57, 1-10, https://doi.org/10.1016/0021-9673(71)80001-8
. [all data]
Notes
Go To: Top, Normal alkane RI, non-polar column, custom temperature program, References
- Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.
- Customer support for NIST Standard Reference Data products.