2-C14H26

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Mass spectrum (electron ionization)

Go To: Top, Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Spectrum

Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.

Mass spectrum
For Zoom
1.) Enter the desired X axis range (e.g., 100, 200)
2.) Check here for automatic Y scaling
3.) Press here to zoom

Additional Data

View image of digitized spectrum (can be printed in landscape orientation).

Due to licensing restrictions, this spectrum cannot be downloaded.

Owner NIST Mass Spectrometry Data Center
Collection (C) 2014 copyright by the U.S. Secretary of Commerce
on behalf of the United States of America. All rights reserved.
Origin B. Derendyaev, Novosibirsk Institute of Organic Chemistry
NIST MS number 139959

All mass spectra in this site (plus many more) are available from the NIST/EPA/NIH Mass Spectral Library. Please see the following for information about the library and its accompanying search program.


Gas Chromatography

Go To: Top, Mass spectrum (electron ionization), References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Kovats' RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillaryOV-101110.1464.Kuningas, Rang, et al., 1990He; Column length: 50. m; Column diameter: 0.25 mm
CapillaryApiezon L150.1451.Rang, Kuningas, et al., 1976N2; Column length: 50. m; Column diameter: 0.25 mm
CapillaryApiezon L170.1451.Rang, Kuningas, et al., 1976N2; Column length: 50. m; Column diameter: 0.25 mm
CapillaryApiezon L190.1451.Rang, Kuningas, et al., 1976N2; Column length: 50. m; Column diameter: 0.25 mm

Kovats' RI, polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillaryPEG-20M80.1628.3Orav, Kuningas, et al., 1993100. m/0.25 mm/0.12 μm
CapillaryPEG-20M80.1651.8Orav, Kuningas, et al., 1993100. m/0.25 mm/0.24 μm
CapillaryPEG-20M80.1652.5Orav, Kuningas, et al., 199360. m/0.32 mm/0.25 μm
CapillaryPEG 4000110.1664.Rang, Orav, et al., 1988 
CapillaryPEG 4000120.1664.Rang, Orav, et al., 1988 
CapillaryPEG 4000140.1666.Rang, Orav, et al., 1988 
CapillaryPEG 4000150.1665.Rang, Orav, et al., 1988 
CapillaryPEG 4000160.1667.Rang, Orav, et al., 1988 
CapillaryPEG-20M80.1628.3Orav, Kuningas, et al., 1985Column length: 100. m; Column diameter: 0.25 mm
CapillaryPEG-20M80.1651.8Orav, Kuningas, et al., 1985Column length: 100. m; Column diameter: 0.25 mm

References

Go To: Top, Mass spectrum (electron ionization), Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Kuningas, Rang, et al., 1990
Kuningas, K.; Rang, S.; Kailas, T., Relationship between the structure and retention of n-alkenes and n-alkynes on silicone phases, J. Chromatogr., 1990, 520, 137-148, https://doi.org/10.1016/0021-9673(90)85094-C . [all data]

Rang, Kuningas, et al., 1976
Rang, S.; Kuningas, K.; Orav, A.; Eisen, O., Capillary gas chromatography of n-alkynes. I. Retention indices, J. Chromatogr., 1976, 119, 451-460, https://doi.org/10.1016/S0021-9673(00)86807-7 . [all data]

Orav, Kuningas, et al., 1993
Orav, A.; Kuningas, K.; Rang, S., A comparison of different retention index systems with unsaturated and aromatic hydrocarbons in capillary gas chromatography on PEG 20MK, Chromatographia, 1993, 37, 7/8, 411-414, https://doi.org/10.1007/BF02272257 . [all data]

Rang, Orav, et al., 1988
Rang, S.A.; Orav, A.E.; Kuningas, K.R.; Meister, A.E.; Strense, T.V.; Eisen, O.G., Gas-Chromatographic Characteristics of unsaturated hydrocarbons, Academy of Sciences of Estonia SSR, Tallinn, Estonia SSR, 1988, 208. [all data]

Orav, Kuningas, et al., 1985
Orav, A.; Kuningas, K.; Rang, S.; Eisen, O., Capillary gas chromatography of n-tridecenes, n-tetradecenes and C10-C14 n-alkynes on polyethylene glycol 20m of different polarity, Eesti NSV Tead. Akad. Toim. Keem., 1985, 34, 2, 105-113. [all data]


Notes

Go To: Top, Mass spectrum (electron ionization), Gas Chromatography, References